WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
3D Acoustic Cavity Helmholtz · Standing Waves · SPL 132 dBAutomociónB-Rep sólido 3D

Expansion Chamber Muffler: 3D Acoustic Cavity Helmholtz Eigenmodes, Standing Waves & Sound Pressure Level (SPL)

Automotive expansion chamber reactive silencer cavity solved via the 3D Helmholtz acoustic wave equation with non-reflecting Robin outlet impedance and sound pressure level (SPL) field visualization.

Internal combustion exhaust mufflers, HVAC ducts, and intake plenums attenuate airborne noise through reactive acoustic impedance mismatches and chamber resonances. This model analyzes a 3D cylindrical expansion chamber (Ø90 × 120 mm) connected to Ø30 mm coaxial inlet and outlet pipes (expansion area ratio m = 9). Solved with WebCAE's native 3D Helmholtz acoustic cavity solver, standing wave anti-nodes and sound pressure levels (SPL) are computed for targeted transmission loss tuning.

✓ 3D Helmholtz Acoustic Wave Equation✓ Cavity Eigenmodes & Standing Wave Patterns✓ Non-Reflecting Robin Radiation Impedance✓ Sound Pressure Level (SPL, dB) Mapping
Contenedor .wce listo con campos de resultados
1,680 TET4 (475 nodes) · 5 acoustic modes (f₁ = 1,561 Hz) · Robin Z = 413 Rayl · p_max = 118.5 Pa · SPL 132.4 dB
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Expansion Chamber Muffler: 3D Acoustic Cavity Helmholtz Eigenmodes, Standing Waves & Sound Pressure Level (SPL)
1,680 TET4 (475 nodes) · 5 acoustic modes (f₁ = 1,561 Hz) · Robin Z = 413 Rayl · p_max = 118.5 Pa · SPL 132.4 dBAbrir 3D ↗
Cavity Fluid Mesh
1,680 TET4 (475 nodes, air medium)
Acoustic Medium
c₀ = 343 m/s, ρ₀ = 1.204 kg/m³
Fundamental Mode
f₁ = 1,560.9 Hz (Helmholtz standing wave)
Peak Pressure
|p|_max = 118.5 Pa (cavity antinode)
Peak SPL
132.4 dB (inlet expansion chamber)

1. Geometría y malla FEA

  • •3D B-Rep CAD model (`muffler_cavity.step`, 8 CAD faces, total length 220 mm, chamber Ø90 mm).
  • •1,680 TET4 acoustic cavity fluid elements, 475 nodes.
  • •Acoustic fluid medium (air at 20°C): speed of sound c₀ = 343 m/s, density ρ₀ = 1.204 kg/m³, characteristic acoustic impedance Z₀ = 413 Rayl (Pa·s/m).

2. Cargas y condiciones de contorno

  • •Acoustic velocity excitation applied at the inlet port face (`surface number 33`, Ø30 mm).
  • •Non-reflecting anechoic Robin impedance radiation boundary applied at the outlet port (`surface number 32`, Z = 413 Rayl).
  • •Rigid sound-hard acoustic boundary condition on chamber outer walls (`surface number 27, 28, 29, 30, 31`, ∂p/∂n = 0).

3. Resultados de simulación y conclusiones

  • ✓5 acoustic cavity resonance modes identified: fundamental longitudinal standing wave at f₁ = 1,560.9 Hz, followed by higher modes at 2,238.1 Hz, 2,518.4 Hz, and 2,963.0 Hz.
  • ✓Maximum standing wave acoustic pressure reaches |p|_max = 118.5 Pa at the expansion chamber endplate.
  • ✓Sound pressure level spans 74.2 to 132.4 dB, clearly revealing internal acoustic quarter-wave resonance nodes.
Flujo de ingeniería y valor empresarial

WebCAE's 3D acoustic Helmholtz solver gives NVH and automotive powertrain engineers immediate insight into muffler cavity resonances, insertion loss, and airborne noise suppression.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad