WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
3D CFD · API 6A Throttling · 12.5k TetsPetróleo, gas y offshoreDinámica de fluidos 3D (CFD RANS)

Throttled API 6A Gate Valve Internal Flow: Vena Contracta Jet & Pressure Drop (CFD)

3D turbulent water flow (RANS k-ω SST, U_in = 3.5 m/s) through a partially throttled (35% open) DN80 high-pressure gate valve passage, resolving the 24.1 m/s vena contracta jet, 1.69 MPa pressure drop, and downstream recirculation vortex.

When a high-pressure oilfield gate valve operates in a partially throttled position during flowback or choke transitions, the descending gate slab restricts the bore into a crescent-shaped orifice. This 3D CFD model represents the internal fluid volume (D_fluid) of an API 6A DN80 (Ø80 mm bore) gate valve throttled to 35% open with an expanded upper bonnet chamber. Water enters at U_in = 3.5 m/s (ρ = 998.2 kg/m³). The flow accelerates sharply beneath the lower edge of the gate into a 24.06 m/s vena contracta jet (6.87× inlet velocity), inducing a static pressure drop of Δp = 1,686.9 kPa (1.69 MPa), a localized low-pressure separation pocket behind the gate (−802.2 kPa gauge), and an axial hydraulic thrust of F_X = 5,482.0 N acting on the gate and body walls.

✓ Internal Valve Flow & Throttling Loss (Δp)✓ Menter k-ω SST Turbulence Model (Water)✓ Vena Contracta High-Speed Jet & Cavitation Risk Zone✓ Hydraulic Axial Thrust on Gate Slab
Contenedor .wce listo con campos de resultados
12.5k tets · |U|_max = 24.1 m/s · Δp = 1.69 MPa · Gate Force F_X = 5.48 kN
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Throttled API 6A Gate Valve Internal Flow: Vena Contracta Jet & Pressure Drop (CFD)
12.5k tets · |U|_max = 24.1 m/s · Δp = 1.69 MPa · Gate Force F_X = 5.48 kNAbrir 3D ↗
Fluid & Turbulence
Water (ρ = 998.2 kg/m³) · k-ω SST
Bore & Opening
DN80 (Ø80 mm) · 35% Open
Finite Volume Mesh
12,469 tets (3,419 nodes)
Vena Contracta Jet
24.06 m/s (6.87× U_in)
Pressure Drop Δp
1,686.9 kPa (1.69 MPa)
Axial Gate Force F_X
5,482.0 N (5.48 kN)
Shear Vorticity |ω|_max
2,902.3 s⁻¹ (Q = 7.08×10⁵ s⁻²)

1. Geometría y malla FEA

  • •Single B-Rep internal fluid passage (D_fluid): Ø80 mm upstream and downstream pipe bores (L = 420 mm total, X ∈ [-180, 240] mm) connected through a central bonnet chamber throttled by a solid gate slab.
  • •Unstructured 3D tetrahedral mesh: 12,469 tetrahedra and 3,419 nodes (volume discretization error 0.50%).
  • •Working fluid: liquid water (ρ = 998.2 kg/m³, dynamic viscosity μ = 1.002×10⁻³ Pa·s) solved with Menter k-ω SST turbulence.
  • •Directly complements the structural API 6A `gate_valve_body` solid stress case by resolving the internal hydrodynamic pressure and jet erosion zones.

2. Cargas y condiciones de contorno

  • •Upstream circular pipe inlet at X = −180 mm (surface number 1): uniform water velocity U_in = 3.5 m/s along +X ([1, 0, 0]).
  • •Downstream circular pipe outlet at X = +240 mm (surface number 18): static gauge pressure p_out = 0 Pa.
  • •All internal pipe walls, bonnet cavity surfaces, and gate slab faces (surfaces 2–17): viscous no-slip wall (u = 0).

3. Resultados de simulación y conclusiones

  • ✓High-velocity vena contracta jet beneath the gate reaches |U|_max = 24.06 m/s (6.87× U_in), identifying the primary seat-ring erosion zone.
  • ✓Area-averaged inlet-to-outlet static pressure drop is Δp = 1,686.9 kPa (1.69 MPa), with upstream stagnation pressure reaching +1,689.1 kPa and post-gate vortex core suction reaching −802.2 kPa.
  • ✓Net axial hydrodynamic force acting on the throttled gate and internal passage walls is F_X = 5,482.0 N (5.48 kN), required for sizing the valve stem actuator.
Flujo de ingeniería y valor empresarial

Pipeline and valve manufacturers use WebCAE CFD to calculate flow coefficients (Cv/Kv), seat erosion velocities, cavitation margins, and stem actuator thrust forces directly from 3D CAD passages.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.