Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
Industrial Silo with Conical Hopper on Columns
Verification of stepped shell wall stability under Janssen bulk solid lateral pressure and vertical wall friction for an elevated industrial silo.
Elevated industrial silos and mineral storage bins suffer complex loading from bulk solids: lateral bursting pressure combined with cumulative vertical frictional drag along the shell walls that induces high axial compression. This axial compressive stress field creates severe susceptibility to elephant's foot buckling and diamond-pattern shell collapse. WebCAE validates the stepped-thickness cylinder, transition ring girder, conical discharge hopper, and column substructure.
1. Geometría y malla FEA
- •Ø8.0 m cylindrical silo (height 24.5 m) with 3 stepped wall tiers (t = 10, 8, and 6 mm), conical roof, and conical hopper (t = 12 mm)
- •16 tubular perimeter support columns Ø320×20 mm (z = 0..8 m) with intermediate ring girder at z = 4 m and diagonal cross braces Ø160×10 mm
- •Heavy transitional ring box beam 400×300 mm at z = 8.0 m supporting the hopper-cylinder junction, plus longitudinal stringers
- •Model composed of 768 MITC4 quadrilateral shell elements and 832 Timoshenko beam elements (5,088 DOFs)
2. Cargas y condiciones de contorno
- •Rigid fixed foundation supports at base of all 16 steel columns at ground level (z = 0)
- •Janssen theoretical pressure profile: radial outward pressure stepped from 30 kPa at top to 90 kPa at base and 120 kPa in hopper
- •Cumulative vertical wall friction load 2.4 MN acting downwards combined with 1.5 MN bulk solid dead weight on the hopper
3. Resultados de simulación y conclusiones
- ✓Critical buckling factor λ₁ = 42.73 confirms robust stability reserve against axial wall compression and elephant's foot buckling
- ✓Fundamental swaying natural frequency f₁ = 9.289 Hz ensures dynamic safety against wind and seismic excitation
- ✓Transition ring beam maintains circular shape without out-of-round ovalization under high column point reactions
Agricultural storage and bulk materials engineering companies utilize WebCAE to automate Eurocode EN 1993-4-1 silo design checks. Rapid parametric assessment of stepped wall thicknesses and ring stiffeners allows cutting steel consumption by up to 15% while eliminating catastrophic buckling risks.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)