WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
Tension-Spoke Wheel · Cantilever A-Frame · 1.3k DOFObra civil y puentesLáminas MITC4 y vigas

London Eye Cantilevered Tension-Spoke Observation Wheel

120 m diameter observation wheel with 24 passenger capsules, inclined tubular A-frame support legs, circular hub spoke flanges (Ø 6.4 m), 3D bicycle-spoke cable triangulation, backstays, and boarding pier.

The London Eye (Millennium Wheel) is the world's tallest cantilevered observation wheel, suspended over the River Thames on a single side by a pair of 58 m inclined tubular steel A-frame legs anchored by heavy cable backstays. Rather than relying on a rigid lattice truss, the 120 m rim functions like a giant bicycle wheel, sustained entirely by tensioned spiral wire-rope cables radiating from a central spindle hub to 24 exterior passenger capsule nodes. WebCAE computes static rim sag under eccentric capsule gravity, A-frame compression, lateral wind drift, natural rocking modes, and out-of-plane wheel rim buckling margins.

✓ Pre-Tensioned Cable Spoke Wheel Dynamics✓ Cantilevered A-Frame Compression Legs✓ Passenger Capsule Eccentric Dead Load✓ Out-of-Plane Wheel Rim Buckling
Contenedor .wce listo con campos de resultados
Ø 120 m · 579 beams · 48 quads · |u| = 423 mm · f₁ = 0.13 Hz · λ₁ = 20.9
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
London Eye Cantilevered Tension-Spoke Observation Wheel
Ø 120 m · 579 beams · 48 quads · |u| = 423 mm · f₁ = 0.13 Hz · λ₁ = 20.9Abrir 3D ↗
Wheel Diameter
Ø 120.0 m · Hub Elevation 70.0 m
Passenger Capsules
24 observation capsules (40 kN each)
Support Structure
Inclined A-frame legs (Ø 2.0 m) + backstays
Tension Spoke Elements
579 beam/cable members
Degrees of Freedom
1,332 DOF
Max Rim Deflection
|u| = 423 mm
Fundamental Frequency
f₁ = 0.13 Hz (lateral rocking)
Buckling Factor
λ₁ = 20.9

1. Geometría y malla FEA

  • •Geometry: 120 m outer rim diameter, central spindle hub at elevation 70 m, twin inclined tubular A-frame legs (Ø 2.0 m) anchored to Thames bank foundation caissons.
  • •Tension spoke system: 64 high-strength pre-tensioned spiral wire-rope cable elements radiating in 3D triangulation between the two spindle hub rings and 24 rim node stations.
  • •Rim & capsules: circular tubular chord rim (Ø 1.0 m) carrying 24 perimeter passenger capsules (40 kN each), backed by boarding pier platform quads.
  • •Discretization: 242 nodes, 579 beam/cable elements, 48 MITC4 shell quads, 1,332 total DOFs with verified hub spindle kinematic compatibility.

2. Cargas y condiciones de contorno

  • •Fixed boundary conditions (all 6 DOFs constrained) at the 2 A-frame foundation leg bases and 2 cable backstay ground anchorages (z = 0).
  • •Gravity loads including self-weight of steel framing and 24 passenger capsule point loads (40 kN each) applied along the rim circumference.
  • •Lateral storm wind force (15 kN/node) acting perpendicular to the wheel plane simulating Thames estuary gales.

3. Resultados de simulación y conclusiones

  • ✓Maximum static rim displacement |u| = 423 mm under combined eccentric passenger loading and lateral wind gust.
  • ✓Fundamental natural frequency f₁ = 0.13 Hz represents lateral pendulum sway of the cantilevered wheel and pylon.
  • ✓Linear elastic buckling factor λ₁ = 20.9 verifies high stability against out-of-plane buckling of the slender compressed rim and A-frame legs.
Flujo de ingeniería y valor empresarial

WebCAE delivers lightweight, accessible finite element modeling for landmark observation wheels, cable-spoke structures, and guyed towers, validating tension cable efficiency and aeroelastic frequencies directly in web browsers.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad