WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
Cable-Stayed Viaduct · Box Girder Deck · 936 DOFObra civil y puentesLáminas MITC4 y vigas

Millau Multi-Span Cable-Stayed Viaduct

Parametric multi-span cable-stayed bridge model with two inverted-Y split pylons H = 75 m, 21 internal box-girder diaphragms, fan stay cables, and MITC4 quad deck.

The Millau Viaduct represents an iconic achievement in multi-span cable-stayed engineering, spanning deep valleys using slender concrete piers, inverted-Y steel split pylons, and an aerodynamic closed trapezoidal steel box girder. This 200 m segment model includes two full pylons (H = 75 m) with 16 stay cable stays each, orthotropic top roadway shell, bottom flange, inclined webs, and 21 transverse internal diaphragms. WebCAE computes static girder sag, pylon head sway under deck wind pressure, vibration mode shapes, and overall structural stability.

✓ Multi-Span Cable-Stayed Dynamics✓ Trapezoidal Orthotropic Box Girder✓ Internal Diaphragm Shear Rigidity✓ Inverted-Y Pylon Buckling
Contenedor .wce listo con campos de resultados
200 m span · 198 beams · 162 quads · |u| = 53.2 mm · f₁ = 1.50 Hz · λ₁ = 71.0
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Millau Multi-Span Cable-Stayed Viaduct
200 m span · 198 beams · 162 quads · |u| = 53.2 mm · f₁ = 1.50 Hz · λ₁ = 71.0Abrir 3D ↗
Total Length
200.0 m (multi-span segment)
Pylon Height
75.0 m (inverted-Y steel pylon)
Box Diaphragms
21 internal stiffening plates
Mesh Elements
198 beams · 162 MITC4 quads
Degrees of Freedom
936 DOF
Max Displacement
|u| = 53.2 mm
Fundamental Frequency
f₁ = 1.50 Hz
Buckling Factor
λ₁ = 71.0

1. Geometría y malla FEA

  • •Deck structure: 200 m long trapezoidal steel box girder (top flange 10 m wide at z = 38 m, bottom flange 6 m wide at z = 35 m, inclined side webs) formed by 162 MITC4 quad elements.
  • •Internal stiffening: 21 transverse diaphragms spaced at 10 m along the girder preventing cross-section distortion, reinforced by top and bottom longitudinal tee stiffeners.
  • •Pylons & stays: twin inverted-Y pylons (pylon shaft H = 75 m, split legs straddling the box girder) supporting 32 high-strength stay cables arranged in semi-fan formation.
  • •Discretization: 156 nodes, 198 beam elements, 162 shell quads, 936 system DOFs with continuous displacement compatibility between box webs and diaphragms.

2. Cargas y condiciones de contorno

  • •Rigid ground foundation supports (all 6 DOFs) at pier bases (z = 0) and roller/pinned abutment bearings at deck ends (x = ±100 m).
  • •Lateral wind pressure (10 kN/node) acting on the exposed deck edge and aerodynamic pylon shafts.
  • •Dead weight of structural steel (E = 210 GPa, ρ = 7,850 kg/m³) plus distributed roadway pavement.

3. Resultados de simulación y conclusiones

  • ✓Maximum mid-span vertical sag |u| = 53.2 mm under combined permanent dead load and lateral wind.
  • ✓Fundamental mode frequency f₁ = 1.50 Hz represents symmetric vertical bending of the central cable-stayed span.
  • ✓Linear elastic buckling load factor λ₁ = 71.0 demonstrates superior stability reserves in the inverted-Y pylon shafts under stay pre-tension thrust.
Flujo de ingeniería y valor empresarial

WebCAE streamlines multi-span cable-stayed bridge assessments, allowing infrastructure teams to evaluate box-girder diaphragm spacing, pylon stability, and cable tuning in an agile web environment without multi-gigabyte workstation installations.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad