Solucionadores
Estático, modal, Kσ, contacto, CFD
130 kN Jet · 51k DOFEnergía, eólica y silosB-Rep sólido 3D

Pelton Hydro Turbine Runner (12 Buckets)

High-head hydroelectric impulse turbine bucket root bending and hydrodynamic jet impingement fatigue analysis.

High-head Pelton hydro turbines operate under concentrated high-velocity water jets exceeding 100 m/s, producing intense cyclical shock impacts on each bucket splitter and bowl. The root attachment fillet joining the bucket to the central runner disk represents a notorious crack initiation hot spot due to combined centrifugal tension and jet cantilever bending. This structural analysis calculates peak von Mises stresses and bowl deflection under a 130 kN single-nozzle water jet impact.

✓ 3D Linear Static✓ Hydroelectric Machinery✓ High-Cycle Fatigue Screening✓ Complex B-Rep Solid
Contenedor .wce listo con campos de resultados
63k tets · σ_vm = 109.6 MPa · |u| = 0.741 mm
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Pelton Hydro Turbine Runner (12 Buckets)
63k tets · σ_vm = 109.6 MPa · |u| = 0.741 mmAbrir 3D ↗
Material
CA6NM Stainless Steel (13Cr4Ni)
Mesh Elements
63,400 tets
Degrees of Freedom
51,200 DOF
Peak von Mises Stress
109.6 MPa
Max Displacement
0.741 mm
Solver Runtime
1.1 s (Desktop) / 4.3 s (WASM)

1. Geometría y malla FEA

  • •Martensitic stainless casting steel CA6NM / 13Cr4Ni (E = 205 GPa, ν = 0.28, yield strength 550 MPa).
  • •Monolithic CNC-milled runner disk with 12 dual-cavity ellipsoidal buckets, knife-edge flow splitters, and entrance cutouts.
  • •Central mounting hub with Ø240 mm shaft bore and 8 precision reamed coupling bolt holes.
  • •Conformal 3D tetrahedral mesh of 63,400 elements and 51,200 active degrees of freedom.

2. Cargas y condiciones de contorno

  • •Fixed constraint on the internal cylindrical bore and rear clamping flange face of the turbine shaft hub.
  • •Normal hydrodynamic jet impact force of 130 kN distributed across the active splitter knife-edge and inner bowl surfaces of the loaded bucket.
  • •Rotational body force field corresponding to nominal 750 rpm operating speed applied across all elements.

3. Resultados de simulación y conclusiones

  • ✓Peak von Mises stress σ_vm = 109.6 MPa located at the root fillet joining the bucket backside to the runner rim.
  • ✓Maximum displacement magnitude |u| = 0.741 mm situated at the outermost bucket lip tip.
  • ✓Safety factor SF = 5.02 against yield strength, confirming exceptional structural integrity against cavitation and fatigue.
Flujo de ingeniería y valor empresarial

Hydro turbine equipment manufacturers analyze intricate 3D blade and bucket geometries in WebCAE directly from STEP files without conversion errors. Instant solver response inside the browser enables rapid evaluation of root fillet variations to maximize turbine lifespan.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad