WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
Static + Modal + Buckling · 74k DOFObra civil y puentesLáminas MITC4 y vigas

60-Story Moment-Frame & Core High-Rise

Classical high-rise dual system: perimeter moment-resisting frame shear lag and central shear wall core interaction.

As a fundamental structural engineering benchmark, the classic dual system combines an interior RC elevator core with an exterior moment-resisting steel frame comprising 36 columns and continuous floor spandrel girders. Because spandrel girders bend in double curvature, shear lag reduces the effectiveness of inner perimeter columns compared to corner members. WebCAE computes the exact load sharing between core wall shear and perimeter frame portal action, checking lateral sway, buckling stability, and modal frequencies.

✓ Dual Moment-Resisting Frame✓ Shear Core Interaction✓ Geometric Stiffness Buckling K_σ✓ Wind-Induced Sway Analysis
Contenedor .wce listo con campos de resultados
u_top = 0.298 m · λ₁ = 7.21 · f₁ = 0.194 Hz
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
60-Story Moment-Frame & Core High-Rise
u_top = 0.298 m · λ₁ = 7.21 · f₁ = 0.194 HzAbrir 3D ↗
Dimensions
Height 240.0 m · Base 40.5 × 40.5 m
Mesh Elements
14,256 quads · 5,184 beams
Degrees of Freedom
74,300 DOF
Top Deflection
u_top = 0.298 m (wind)
Buckling Factor
λ₁ = 7.21 (elastic K_σ)
Fundamental Frequency
f₁ = 0.194 Hz
Solver Runtime
3.4 s (native static + modal)

1. Geometría y malla FEA

  • •Building dimensions: 240.0 m total height, 60 stories, 40.5 × 40.5 m footprint, with a central 13.5 × 13.5 m core (t = 0.6 m).
  • •Perimeter moment frame: 36 box columns spaced at 4.5 m (stepped in 3 height tiers: 510 × 43, 408 × 34, 280 × 23 mm) tied by 255 × 21 mm spandrel beams at every floor.
  • •Concrete slabs: 60 trapezoidal diaphragm levels tying the inner core walls to the facade columns, transferring lateral wind diaphragm shear.
  • •Mesh composition: 14,256 shell quads, 5,184 beam elements, 11,608 nodes (69,120 active DOFs, 74,000+ total DOFs).

2. Cargas y condiciones de contorno

  • •Rigid base fixity across all 36 column footings and 6 core wall perimeter base segments.
  • •Full height boundary-layer wind profile delivering 18.21 MN total base shear and overturning moment of 2,941.6 MN·m.
  • •Full gravitational dead load accounting for concrete density and structural steel sections to establish baseline axial compression.

3. Resultados de simulación y conclusiones

  • ✓Top lateral wind deflection u_top = 0.298 m (within acceptable drift limit H/505, with Vierendeel frame action absorbing 42% of base overturning).
  • ✓Critical gravitational load factor λ₁ = 7.21 based on full 3D geometric stiffness matrix K_σ.
  • ✓Fundamental lateral vibration mode f₁ = 0.194 Hz, demonstrating characteristic coupled core-frame flexural-shear deformation profile.
Flujo de ingeniería y valor empresarial

Civil engineering practices use WebCAE as an instantaneous validation tool to compare classic moment-frame solutions with outrigger or diagrid alternatives using uniform material budgets. The portable .wce container lets project managers and peer reviewers check frame forces, column P-M interaction, and story drifts on standard laptops.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad