Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
Willis Tower: 442 m Bundled Tube Skyscraper (Sears Tower)
Fazlur Khan 3×3 bundled tube concept, 4 stepped setback tiers, framed tube perimeter, and twin broadcast spires.
Verify the structural efficiency of the bundled-tube concept in minimizing shear lag across diaphragms, resisting lakefront storm winds, and ensuring stability across all 4 setback tiers.
1. Geometría y malla FEA
- •9 structural steel framed tubes in a 3×3 matrix (each tube 22.5×22.5 m, total base 67.5×67.5 m)
- •Tier 1 (z = 0 to 200 m, level 50): All 9 tubes rise together as a rigid composite bundled tube
- •Tier 2 (z = 200 to 260 m, level 66): 2 diagonally opposite corner tubes terminate, leaving 7 active tubes
- •Tier 3 (z = 260 to 360 m, level 90): 2 more corner tubes drop off, creating an iconic cruciform 5-tube tower
- •Tier 4 (z = 360 to 442 m, roof): 3 more tubes terminate, leaving central 2-tube core rising to roof
- •Twin broadcast spires rising from the central tube cores from z = 442 m to 520 m
- •Framed tube columns and deep spandrel beams with diaphragm caps at each setback level
2. Cargas y condiciones de contorno
- •Base column nodes fixed in 6 DOFs across all 16 column lines at ground z = 0
- •Self-weight gravity with floor and mechanical equipment dead loads
- •Chicago lakefront lateral wind pressure along +X with atmospheric boundary layer gradient
3. Resultados de simulación y conclusiones
- ✓Bundled tube design exhibits minimal shear lag with uniform axial stress across perimeter column lines
- ✓Smooth drift curve up to 442 m validates the aerodynamic and structural logic of progressive setbacks
- ✓Fundamental sway frequency f₁ and torsional modes reflect the shifting center of rigidity across tiers
Validates historical benchmark tall-building structural systems in modern cloud FEA, providing immediate educational and professional insight into tube mechanics.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)
Pregunta a un ingeniero sobre tu modelo
Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.
¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?
Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.