Longitudinal harmonic response of rod (P1 Tet4)
Harmonic analysisPASS · 0.03%Axial dynamic frequency response and resonance amplitude of a steel rod under longitudinal harmonic tensile force, verified against exact 1D continuous wave propagation velocity and analytical resonance amplification factor.
- Tolerancia:
- 5%
Abrir y resolver en el navegadorInicie sesión o regístrese para abrir este modelo verificado en WebCAE
Abrir y resolver en el navegadorPlanteamiento del problema
- Geometría
- Steel rod: L = 100 mm, b = 10 mm, h = 10 mm, linear tetrahedral mesh (TET4).
- Material
- Structural steel: E = 200 GPa, ν = 0.3, ρ = 7850 kg/m³.
- Condiciones de contorno
- Fixed at root face (x = 0); harmonic axial tensile force F_x = 1000 N at free face (x = 100 mm).
- Magnitud medida
- Fundamental axial resonance frequency f_axial (analytical: c / (4L) = 12930.4 Hz) and tip peak vibration amplitude under 2% modal damping (analytical: 0.03860 mm).
Terminal WebCAE
Pegue estos comandos en el panel Terminal dentro de WebCAE. Utilizan el mismo DSL de texto que la aplicación; ejecute un comando por línea:
units mm
material E=210e9 nu=0.0 density=7850
primitive box dx=100 dy=10 dz=10
mesh tet size=5 order=1
fix surface number 1
load surface number 2 force=1000 component=x
solve harmonic fmin=12000 fmax=14000 npoints=200 zeta=0.05 nmodes=10
probe frequency mode=6
probe harmonic_amplitude x=100 freq=12926.1Comparación de resultados
| Valor de referencia | f₁ = 12930.4 Hz, u_res = 0.03860 mm |
| Resultado WebCAE | f₁ = 12926.1 Hz, u_res = 0.03860 mm |
| Desviación | 0.03% |
| Tolerancia | 5% |
| Estado | PASS · 0.03% |
| Familia de elementos | Elemento sólido |
| Detalles de malla | P1 TET4 first-order mesh, 346 elements, 164 nodes |
Actualizado: 2026-08-30 · anterior a la numeración de versiones (anterior a 0.1.1)