WebCAE
← Todos los casos

Random Vibration — Miles Equation Cantilever PSD

Vibration and Random DynamicsPASS · 0.08%

Verification of random vibration power spectral density (PSD) response against classical Miles' closed-form equation for a single-degree-of-freedom base-excited system.

Tolerancia:
5%
Abrir y resolver en el navegadorInicie sesión o regístrese para abrir este modelo verificado en WebCAE
Abrir y resolver en el navegador

Planteamiento del problema

Geometría
Cantilever oscillator with fundamental frequency fn = 100 Hz, modal damping ratio zeta = 0.02 (amplification factor Q = 25).
Material
Linear modal dynamics with modal participation factor Gamma = 1.0.
Condiciones de contorno
Kinematic base excitation under uniform white-noise acceleration PSD Sa = 0.05 g^2/Hz from 10 to 500 Hz.
Magnitud medida
Miles' equation gives displacement RMS z_rms = sqrt(pi * Sa / (4 * zeta * fn^3 * (2*pi)^4)) = 0.03513 mm and acceleration RMS a_rms = sqrt(pi/2 * fn * Q * Sa) = 14.0125 g. Full numerical transfer-function integration verifies within 1%.

Terminal WebCAE

Pegue estos comandos en el panel Terminal dentro de WebCAE. Utilizan el mismo DSL de texto que la aplicación; ejecute un comando por línea:

units mm
modal oscillator fn=100 zeta=0.02 participation=1.0
random vibration base_psd=0.05 f_start=10 f_stop=500 unit=g2_per_hz
solve psd method=modal_integration
extract rms_displacement rms_acceleration

Comparación de resultados

Valor de referenciaz_rms=0.03513 mm, a_rms=14.0125 g
Resultado WebCAEz_rms=0.03510 mm, a_rms=13.9984 g
Desviación0.08%
Tolerancia5%
EstadoPASS · 0.08%
Detalles de malla1- modal oscillator fn=100 Hz, adaptive clustered FRF grid (500 pts)

Actualizado: 2026-10-27 · versión no registrada

Ejecutar simulación FEM en línea en el navegadorBiblioteca de elementos finitos WebCAEFlujo CAD → FEM