Coupled nonlinear radiation & κ(T) in transient thermoelasticity (TD2 × T4)
Coupled transient thermoelasticityPASS · <0.01%Coupled transient thermoelasticity driven by nonlinear Stefan–Boltzmann surface radiation (εσ(T⁴ − T_∞⁴)) and temperature-dependent conductivity κ(T). Verifies that the Newton–θ thermal marcher inside the thermoelastic transient solver reproduces the standalone nonlinear thermal transient solution to machine precision and induces the corresponding thermal stress state.Coupled transient thermoelasticity driven by nonlinear Stefan–Boltzmann surface radiation (εσ(T⁴ − T_∞⁴)) and temperature-dependent conductivity κ(T). Verifies that the Newton–θ thermal marcher inside the thermoelastic transient solver reproduces the standalon… mostrar texto completo
- Tolerancia:
- 5%
Planteamiento del problema
- Geometría
- Prismatic bar 50 × 10 × 10 mm; tetrahedral mesh, element size 5 mm.
- Material
- Steel with tabular conductivity κ(T) = 20·(1 + 0.01·T) W/(m·K), E = 200 GPa, ν = 0.3, ρ = 7800 kg/m³, c_p = 460 J/(kg·K), α = 1.2 × 10⁻⁵ K⁻¹.
- Condiciones de contorno
- Initial T₀ = 900 °C, T_ref = 20 °C; surface number 1 clamped (u_x = 0); surface number 2 radiating with ε = 0.85 into T_∞ = 20 °C ambient. Coupled transient solve over 600 s.
- Magnitud medida
- Agreement between the coupled TD2×T4 thermal field and standalone nonlinear heat conduction (max|ΔT| = 0 K) and radiative cooling temperature at t = 600 s.
Terminal WebCAE
Pegue estos comandos en el panel Terminal dentro de WebCAE. Utilizan el mismo DSL de texto que la aplicación; ejecute un comando por línea:
units mm
material E=200000000000 nu=0.3 density=7800 kappa=100000 specific_heat=460 alpha=0.000012
primitive box dx=50 dy=10 dz=10
mesh tet size=5
fix surface number 1
thermal surface number 2 radiation=0.85 ambient=20
solve thermoelastic transient mode=quasistatic dt=5 tend=600 theta=0.5 t0=900 tref=20 frames=3
probe temperature x=0 time=600 id="T600"Comparación de resultados
| Valor de referencia | max|T_TD2 − T_TD1| = 0 КT(600 с) = 695.576 °C |
| Resultado WebCAE | max|T_TD2 − T_TD1| = 0.000 КT(600 с) = 695.581 °C |
| Desviación | <0.01% |
| Tolerancia | 5% |
| Estado | PASS · <0.01% |
| Detalles de malla | tet4, size 5 mm (195 nodes); 108/108 проверок нативного приёмочного стенда TD2×T4 |
Actualizado: 2026-10-27 · versión no registrada