Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
53 m Oil Drilling Derrick & Substructure
Verification of overall structural stability and wind-load resistance under a 300-ton maximum hook load for a 53 m deep drilling rig.
Drilling derricks operate under extreme compressive hook loads during casing running or drill string pullout while concurrently withstanding gale-force storm winds. High slenderness ratio of the 45-meter tapered tower demands rigorous eigenvalue buckling analysis accounting for initial compressive stress states in the legs. WebCAE verifies the substructure box foundation, rotary table deck stiffness, monkey board vibration levels, and crown block framing integrity.
1. Geometría y malla FEA
- •53 m total structure height: 8 m substructure (12×12 m footprint) topped by 45 m tapered derrick (9×9 m base to 2.4×2.4 m top)
- •Lattice tower framing: tubular corner legs Ø360×30 mm, K- and X-braces Ø200×15 mm, and substructure box sills 450×450×30 mm
- •Shell decks: stiffened 12×12 m rotary drill floor (t = 22 mm), monkey board at z = 33 m (t = 10 mm), and crown block platform at z = 53 m (t = 25 mm)
- •FEA model combining 88 MITC4 quadrilateral plate elements and 612 Timoshenko beam elements (1,314 DOFs)
2. Cargas y condiciones de contorno
- •Rigid fixed foundation supports at 16 bottom contact points of the skid substructure beam grid (z = 0)
- •Maximum design hook load Fz = -3.0 MN (300 metric tons) applied centrally to the crown block deck beams
- •Drill pipe setback pressure 80 kPa on the setback area, rotary table mass 25 t, and 25 kN lateral wind load per tier
3. Resultados de simulación y conclusiones
- ✓Critical buckling factor λ₁ = 4.62 exceeds API Spec 4F requirements for maximum permissible hook load
- ✓Fundamental cantilever swaying frequency f₁ = 1.908 Hz prevents dangerous vortex-induced crosswind resonant oscillations
- ✓Substructure box girders maintain minimal angular tilt, preserving drill string vertical alignment through the rotary table
Oilfield equipment manufacturers use WebCAE to verify drilling rigs against API 4F hurricane wind and max hook load standards directly in browser sessions. Fast parameter studies on leg diameter and bracings enable weight reduction while maintaining full stability and worker safety at height.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)
Pregunta a un ingeniero sobre tu modelo
Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.
¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?
Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.