Freeform Shell & Space Frame · S-Wave Roof · 2.0k DOFObra civil y puentesLáminas MITC4 y vigas

Heydar Aliyev Center Freeform Flowing Roof

Flowing freeform S-wave doubly-curved architectural shell roof (72 × 48 m, H = 22 m) reinforced by a bi-directional tubular space-frame grid on braced columns.

Zaha Hadid Architects' Heydar Aliyev Center in Baku established a new paradigm in fluid, continuous architecture, turning walls, roofs, and plazas into a single undulating surface without interior columns. The real-world structure solves this using a massive structural steel space frame clad in glass-fiber reinforced concrete panels. This model reproduces the 72 × 48 m primary S-wave canopy (height 22 m) utilizing an MITC4 quad skin backed by a bi-directional tubular steel space-frame grid and braced columns. WebCAE computes asymmetric snow drift settlements, lateral wind sway, dynamic frequencies, and snap-through buckling capacity.

✓ Freeform Doubly-Curved Architectural Shell✓ Space-Frame Tubular Diagrid Stiffening✓ Lateral Wind Suction & Snow Drift✓ Global Shell Snap-Through Buckling
Contenedor .wce listo con campos de resultados
72×48 m · 670 beams · 216 quads · |u| = 67.6 mm · f₁ = 1.98 Hz · λ₁ = 5.26
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Heydar Aliyev Center Freeform Flowing Roof
72×48 m · 670 beams · 216 quads · |u| = 67.6 mm · f₁ = 1.98 Hz · λ₁ = 5.26Abrir 3D ↗
Canopy Dimensions
72.0 × 48.0 m · Peak Height 22.0 m
Space Frame Members
670 tubular steel members
Cladding Quads
216 MITC4 quad panels (t = 80 mm)
Degrees of Freedom
1,962 DOF
Max Displacement
|u| = 67.6 mm (trough valley)
Fundamental Frequency
f₁ = 1.98 Hz
Buckling Factor
λ₁ = 5.26
Solver Runtime
0.2 s (native modal & static)

1. Geometría y malla FEA

  • •Geometry: flowing doubly-curved S-wave surface (72 m length, 48 m width, 22 m crest elevation, 12 m trough valley) transitioning into an inclined cantilever canopy.
  • •Shell envelope: 216 MITC4 quad elements (t = 80 mm) representing the outer cladding envelope.
  • •Structural steel skeleton: 670 tubular beam elements forming the internal space-frame grid (chords Ø 250×16 mm, diagonals Ø 160×10 mm) and 12 braced boundary support columns.
  • •System size: 327 joints, 670 frame elements, 216 shell quads, 1,962 total DOFs with certified node-to-quad alignment.

2. Cargas y condiciones de contorno

  • •Fixed boundary conditions (all 6 DOFs) at 12 perimeter base columns anchored to concrete pile caps (z = 0).
  • •Asymmetric snow drift (-2.0 kPa on valley trough) combined with lateral wind suction (+1.2 kPa uplift on crest).
  • •Self-weight of structural steel framing and composite cladding (equivalent density 7,850 kg/m³ for steel, 2,100 kg/m³ for skin).

3. Resultados de simulación y conclusiones

  • ✓Maximum vertical static deflection |u| = 67.6 mm located in the wide-span valley trough under combined snow drift and gravity.
  • ✓Fundamental natural frequency f₁ = 1.98 Hz corresponds to global longitudinal sway of the undulating canopy.
  • ✓Elastic buckling load factor λ₁ = 5.26 demonstrates positive structural stability against non-symmetric snap-through under high snow load.
Flujo de ingeniería y valor empresarial

WebCAE equips structural consultants to evaluate complex freeform parametric geometry, validating space-frame sizing, shell-stiffener load paths, and stability criteria directly during design charrettes.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad