Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
Heydar Aliyev Center Freeform Flowing Roof
Flowing freeform S-wave doubly-curved architectural shell roof (72 × 48 m, H = 22 m) reinforced by a bi-directional tubular space-frame grid on braced columns.
Zaha Hadid Architects' Heydar Aliyev Center in Baku established a new paradigm in fluid, continuous architecture, turning walls, roofs, and plazas into a single undulating surface without interior columns. The real-world structure solves this using a massive structural steel space frame clad in glass-fiber reinforced concrete panels. This model reproduces the 72 × 48 m primary S-wave canopy (height 22 m) utilizing an MITC4 quad skin backed by a bi-directional tubular steel space-frame grid and braced columns. WebCAE computes asymmetric snow drift settlements, lateral wind sway, dynamic frequencies, and snap-through buckling capacity.
1. Geometría y malla FEA
- •Geometry: flowing doubly-curved S-wave surface (72 m length, 48 m width, 22 m crest elevation, 12 m trough valley) transitioning into an inclined cantilever canopy.
- •Shell envelope: 216 MITC4 quad elements (t = 80 mm) representing the outer cladding envelope.
- •Structural steel skeleton: 670 tubular beam elements forming the internal space-frame grid (chords Ø 250×16 mm, diagonals Ø 160×10 mm) and 12 braced boundary support columns.
- •System size: 327 joints, 670 frame elements, 216 shell quads, 1,962 total DOFs with certified node-to-quad alignment.
2. Cargas y condiciones de contorno
- •Fixed boundary conditions (all 6 DOFs) at 12 perimeter base columns anchored to concrete pile caps (z = 0).
- •Asymmetric snow drift (-2.0 kPa on valley trough) combined with lateral wind suction (+1.2 kPa uplift on crest).
- •Self-weight of structural steel framing and composite cladding (equivalent density 7,850 kg/m³ for steel, 2,100 kg/m³ for skin).
3. Resultados de simulación y conclusiones
- ✓Maximum vertical static deflection |u| = 67.6 mm located in the wide-span valley trough under combined snow drift and gravity.
- ✓Fundamental natural frequency f₁ = 1.98 Hz corresponds to global longitudinal sway of the undulating canopy.
- ✓Elastic buckling load factor λ₁ = 5.26 demonstrates positive structural stability against non-symmetric snap-through under high snow load.
WebCAE equips structural consultants to evaluate complex freeform parametric geometry, validating space-frame sizing, shell-stiffener load paths, and stability criteria directly during design charrettes.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)
Pregunta a un ingeniero sobre tu modelo
Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.
¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?
Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.