WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
Cable-Net Tent Canopy · Inclined Tripod Mast · 1.2k DOFObra civil y puentesLáminas MITC4 y vigas

Khan Shatyr Catenary Cable-Net Tent Structure

72 m inclined tripod tubular steel mast & Ø 110 m catenary radial-hoop cable-net tent canopy supported on a perimeter concrete compression ring wall.

Norman Foster's Khan Shatyr Entertainment Center in Astana is the world's largest tensile tent structure, rising 72 m on an inclined tripod steel mast to enclose a 110 m diameter microclimate under extreme continental weather (−40°C to +40°C). The structural scheme features an inclined three-legged tubular mast that supports a radial array of tensioned steel cables dropping down in catenary curves to a perimeter concrete compression ring beam, holding an ultra-lightweight three-layer ETFE cushion envelope. WebCAE evaluates mast leg compression, cable-net sag under extreme snow, membrane uplift, and vibration mode shapes.

✓ Inclined Tripod Mast Compression & Guys✓ Catenary ETFE Cable-Net Tension Canopy✓ Perimeter Compression Ring Beam✓ Non-Linear Geometric Sag & Wind Uplift
Contenedor .wce listo con campos de resultados
Ø 110 m · H = 72 m · 405 beams · 192 quads · |u| = 136.2 mm · f₁ = 0.65 Hz · λ₁ = 0.27
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Khan Shatyr Catenary Cable-Net Tent Structure
Ø 110 m · H = 72 m · 405 beams · 192 quads · |u| = 136.2 mm · f₁ = 0.65 Hz · λ₁ = 0.27Abrir 3D ↗
Tent Diameter
Ø 110.0 m · Apex Height 72.0 m
Mast Structure
72 m inclined 3-legged tubular tripod
Catenary Cables
24 radial cables + 6 hoop rings
Membrane Quads
192 MITC4 quad elements (ETFE)
Degrees of Freedom
1,212 DOF
Max Canopy Sag
|u| = 136.2 mm (catenary bay)
Fundamental Frequency
f₁ = 0.65 Hz
Buckling Factor
λ₁ = 0.27 (local cable slack)

1. Geometría y malla FEA

  • •Geometry: 72 m apex elevation, elliptical footprint Ø 110 m at base, inclined tripod steel mast consisting of 3 legs (Ø 1.8 m) converging at the 72 m apex.
  • •Cable-net canopy: 24 radial catenary cables and 6 circumferential hoop cables (Ø 140–160 mm high-strength steel) integrated with 192 MITC4 membrane shell elements (t = 5 mm ETFE composite).
  • •Perimeter base ring: concrete ring beam at z = 8 m supported on 24 perimeter anchor columns resisting radial inward tension forces.
  • •Discretization: 229 nodes, 405 beam/cable members, 192 shell quads, 1,212 total system DOFs with verified cable-membrane tension compatibility.

2. Cargas y condiciones de contorno

  • •Fixed base supports (all 6 DOFs constrained) at the 3 tripod mast footings and 24 perimeter compression ring columns (z = 0).
  • •Extreme continental snow loading and wind suction (-2.0 kPa pressure/suction) acting on the catenary membrane surface.
  • •Self-weight of tubular steel framing and tensile cable elements under pretension.

3. Resultados de simulación y conclusiones

  • ✓Maximum vertical static deflection |u| = 136.2 mm in the catenary mid-span cable bays under combined snow and self-weight.
  • ✓Fundamental mode frequency f₁ = 0.65 Hz corresponds to synchronous breathing and transverse swaying of the tensile cable net.
  • ✓Critical eigenvalue buckling load factor λ₁ = 0.27 reveals sensitive local cable slackening under asymmetric severe snow, highlighting the requirement for tension stiffening.
Flujo de ingeniería y valor empresarial

WebCAE enables tensile architecture specialists to analyze large-span cable-net tents, ETFE structures, and tripod masts, predicting cable tensions, mast buckling loads, and dynamic response in browser-based workflows.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad