WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
Static + Buckling + Modal · 984 DOFMinería y grúasLáminas MITC4 y vigas

48 m Mine Hoist Headframe & Ore Bin

Full-scale structural stability, skip hoist dynamic stiffness, and modal validation for a 48 m steel vertical shaft headframe.

Mine hoist headframes support massive head sheaves transmitting multi-meganewton dynamic rope pull into the foundation while resisting wind and seismic vibrations. The inclined two-leg backstay absorbs the resultant hoist rope pull to prevent tower overturning and excessive horizontal drift. WebCAE verifies overall frame stability with geometric stiffness matrices Kσ, sheave deck dynamic compliance, and bunker wall pressure resistance.

✓ Linear Static✓ Eigenvalue Buckling (Kσ)✓ Modal Vibration✓ MITC4 Shells & Beams
Contenedor .wce listo con campos de resultados
64 quads · 386 beams · λ₁ = 28.34 · f₁ = 2.456 Hz
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
48 m Mine Hoist Headframe & Ore Bin
64 quads · 386 beams · λ₁ = 28.34 · f₁ = 2.456 HzAbrir 3D ↗
Structure Dimensions
10 × 10 m base · H = 48 m
Finite Elements
64 Quads · 386 Beams
Degrees of Freedom
984 DOF
Buckling Factor
λ₁ = 28.34
Fundamental Frequency
f₁ = 2.456 Hz
Solver Runtime
0.4 s (Browser WASM)

1. Geometría y malla FEA

  • •Spatial 48 m vertical tower (10×10 m base, 8 tiers of 6 m) with 7-tier inclined box backstay (x = 28 m anchor base)
  • •Three MITC4 shell decks at z = 12 m, 42 m, and 48 m (16–20 mm plate) plus stiffened pyramidal ore bin (t = 14 mm)
  • •Heavy box columns 500×500×30 mm, backstay legs 600×600×40 mm, I-beam ring ties 400×200 mm, and pipe diagonals Ø250×15 mm
  • •Hybrid finite element model combining 64 MITC4 quadrilateral shell elements and 386 Timoshenko beam members (984 DOFs)

2. Cargas y condiciones de contorno

  • •Rigid foundation anchor supports at 4 tower leg bases (z = 0) and 2 backstay foundation nodes (x = 28 m, z = 0)
  • •Dynamic skip hoist rope tension: vertical pull Fz = -600 kN and horizontal pull Fx = +400 kN towards the backstay
  • •Bunker lateral ore pressure 40 kPa combined with 20 t concentrated equipment mass per sheave platform (z = 42 m and 48 m)

3. Resultados de simulación y conclusiones

  • ✓Critical buckling factor λ₁ = 28.34 guarantees robust elastic stability margin under extreme rope tension
  • ✓Fundamental bending vibration frequency f₁ = 2.456 Hz prevents resonant interaction with skip hoisting frequencies
  • ✓Maximum tower top horizontal drift under 400 kN sheave pull remains within strict operational elevator alignment tolerances
Flujo de ingeniería y valor empresarial

Mining engineering departments use WebCAE to model full-scale headframes with ore bins and sheave decks directly in a web interface without installing heavyweight software. Coupling Timoshenko space frames with MITC4 plate shells achieves instant verification of structural stability and natural vibration frequencies across emergency braking scenarios.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad