Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
Two-Layer Stiffened Shell Buffer Panel with Thickness-Offset Contact
Geometrically nonlinear MITC4 shell-to-shell contact accounting for half-thickness offsets (slaveoffset + masteroffset) and two-sided contact.
Double-skin rockfall shields, dump-body wear liners, and leaf-spring buffer plates consist of thin sheets separated by a small clearance gap. Modeling mid-surfaces without accounting for plate thickness delays contact engagement by (t₁ + t₂)/2. Using WebCAE's thickness-offset shell contact (nlgeom contact slaveoffset=0.003 masteroffset=0.005 twosided=on), the 10 mm mid-surface spacing correctly enforces a 2.0 mm physical clearance between the 6 mm upper sheet and 10 mm lower backing plate, engaging the lower plate into composite bending as soon as deflection exceeds 2 mm.
1. Geometría y malla FEA
- •70 nodes, 48 four-node MITC4 shell quads, and 32 stiffener beam elements (300 active DOFs, footprint 1.2 × 0.8 m).
- •Upper impact skin (Slave): t₁ = 6 mm at z = +10 mm with longitudinal edge stiffeners (16 × 24 mm), slaveoffset = 3 mm.
- •Lower backing plate (Master): t₂ = 10 mm at z = 0 mm with transverse support ribs (20 × 28 mm), masteroffset = 5 mm.
- •Clamped ends at x = 0 and x = 1.2 m; central downward impact load on the upper skin.
2. Cargas y condiciones de contorno
- •Full 6-DOF clamping of all 20 end nodes along x = 0 m and x = 1.2 m on both upper and lower panels.
- •Downward vertical forces applied to the central impact zone of the upper sheet (z = +10 mm).
- •Two-sided shell contact (nlgeom contact slaveoffset=0.003 masteroffset=0.005 twosided=on, penalty=2e8 N/m).
3. Resultados de simulación y conclusiones
- ✓Converges in 6 load steps (22 Newton iterations, 0 cutbacks) with 7 active node-to-surface contact pairs and 0.071 mm max penetration.
- ✓Upper skin deflects by -13.62 mm and drives the lower backing plate down by -12.02 mm across the 2.0 mm initial physical clearance.
- ✓First natural frequency of the double-layer panel is f₁ = 35.97 Hz.
Allows engineers to simulate multi-layer sheet metal assemblies and wear liners with exact thickness offsets directly on shell mid-surfaces.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)
Pregunta a un ingeniero sobre tu modelo
Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.
¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?
Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.