Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
Stepped Drive Shaft, Hub & Parallel Key
Unilateral Mortar contact analysis of torsional load transfer across a parallel keyway under 650 N·m torque.
In a parallel keyed shaft-hub connection under torsion, only the active driving flank of the key carries compressive bearing load while the opposite non-driving flank unloads and separates. Using 3 disconnected component meshes (bonding = 0, mesh components = 3) and unilateral Mortar contact, this model captures the true asymmetric key bearing pressure and keyway fillet stress under 650 N·m transmitted torque.
1. Geometría y malla FEA
- •3 disconnected solid B-Rep bodies (mesh components = 3): stepped shaft Ø50/Ø64 mm, flanged hub with Ø50 mm bore and torque lugs, and DIN 6885 parallel key (14 × 10 × 54 mm).
- •Multi-material configuration: 42CrMo4 alloy steel (E = 210 GPa, ν = 0.29) for shaft; EN-GJS-500-7 ductile iron (E = 169 GPa, ν = 0.28) for hub; C45 carbon steel (E = 205 GPa, ν = 0.29) for parallel key.
- •Independent 2nd-order tetrahedral meshes (TET10) totaling 15,713 elements, 27,350 nodes, and 82,050 DOFs.
- •Unilateral Mortar contact across all 3 body pairs (`body1↔body2`, `body1↔body3`, `body2↔body3`).
2. Cargas y condiciones de contorno
- •Rear shoulder journal and end face of the stepped drive shaft fully fixed (Ux = Uy = Uz = 0).
- •650 N·m torsional couple applied as a tangential force pair (2 × 5.0 kN at radius R = 65 mm) on the hub torque-arm lugs.
- •Axial (Z) guide constraints on the hub and key end faces prevent axial walkout while leaving tangential rotation free.
3. Resultados de simulación y conclusiones
- ✓Peak contact bearing pressure p_contact = 1218.0 MPa along the active driving key flank.
- ✓Peak equivalent von Mises stress σ_vm = 572.0 MPa concentrated at the loaded keyway corner and shear plane of the key.
- ✓Maximum displacement |u| = 0.1571 mm at the outer tips of the hub torque-arm lugs.
Mechanical engineers evaluate true unilateral keyway bearing stresses and shaft notch factors in WebCAE without artificial tension across the unloaded side of the keyway slot.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)
Pregunta a un ingeniero sobre tu modelo
Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.
¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?
Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.