Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.
Split Clamping Hub on Hollow Drive Shaft Assembly (3 Bodies)
Nonlinear 3-body Mortar contact analysis of a two-piece EN-GJS-500-7 split clamping hub squeezing a hollow 42CrMo4 steel shaft under 65 MPa bolt flange preload.
Split clamping hubs transmit high torque without keyways by squeezing two ductile-iron saddle halves directly onto a hollow drive shaft across a 4 mm split gap. Using 3 disconnected B-Rep meshes (bonding = 0, mesh components = 3), this model captures the flexural wrapping of the clamping ears under 65 MPa bolt preload, the radial contact pressure distribution around the Ø50 mm shaft seat, and the hoop compression inside the hollow shaft bore.
1. Geometría y malla FEA
- •3 disconnected B-Rep solids (mesh components = 3): hollow drive shaft (OD = 50 mm, ID = 20 mm, L = 60 mm) and two symmetric split clamping hub halves (OD = 96 mm, flange span 136 mm, width 36 mm, 4 mm split gap).
- •Materials: 42CrMo4 alloy steel shaft (E = 210 GPa, ν = 0.29) and EN-GJS-500-7 ductile iron clamping halves (E = 170 GPa, ν = 0.28).
- •Independent 2nd-order tetrahedral volume meshes (TET10): 8,262 quadratic elements, 16,066 nodes, and 48,198 DOFs.
- •Unilateral frictionless Mortar contact across both semicylindrical R = 25 mm shaft-to-hub interfaces.
2. Cargas y condiciones de contorno
- •End faces of the hollow drive shaft (z = ±30 mm) fixed in all directions (Ux = Uy = Uz = 0), leaving the central clamping span (z = -18..+18 mm) free to deform radially.
- •Lateral and axial symmetry guide constraints (Ux = 0 on outer ear flanks x = ±68 mm, Uz = 0 on rear hub face z = -18 mm) guiding both hub halves strictly along the vertical clamping axis Y.
- •Opposing 65.0 MPa bolt clamping pressure applied across the four horizontal flange bosses at y = ±18 mm.
3. Resultados de simulación y conclusiones
- ✓Peak contact pressure p_contact = 2949.1 MPa along the clamping pinch edges where the split hub ears transition into the Ø50 mm cylindrical seat.
- ✓Peak equivalent von Mises stress σ_vm = 1490.0 MPa in the fillet root of the clamping flange ears and hollow shaft wall.
- ✓Maximum clamping displacement |u| = 0.2528 mm at the outer bolt flanges as the two hub halves wrap around the shaft.
Machinery designers use WebCAE to size split clamping hubs, check ear bending stresses, and predict radial grip pressure without keyway stress concentrations.
14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.
- ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
- ✓Hasta 1,5M+ GDL (solucionador disperso directo)
- ✓Apps nativas para Windows, macOS y Linux (100% offline)
- ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)
Pregunta a un ingeniero sobre tu modelo
Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.
¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?
Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.