WebCAE
WebCAE PlatformEntorno unificado de simulación FEA y CFD: WebAssembly en navegador + versión nativa de escritorio

Inspecciona modelos prerresueltos en tu navegador en 2 s (hasta 300k GDL) o resuelve ensamblajes pesados de más de 1,5M GDL 100% sin conexión en Windows, macOS y Linux.

Versión web (WASM)
Hasta 300k GDL · carga en 2 s
Escritorio nativo (Pro)
Hasta 1,5M+ GDL · 100% sin conexión
Solucionadores
Estático, modal, Kσ, contacto, CFD
Spherical Shell Vaults · Precast Fan Ribs · 6.0k DOFObra civil y puentesLáminas MITC4 y vigas

Sydney Opera House Vaulted Roof Shells

Cascade of 3 pointed spherical vaulted concrete roof shells (65 × 34 m, H = 28 m) with fan precast ribs supported on a stepped podium deck framed by concrete columns.

Jørn Utzon's Sydney Opera House resolved unprecedented architectural freeform geometry by deriving all vaulted roof shells from the surface of a single sphere. The structural design features precast concrete chevron-shaped ribs fanning out from stepped podium hinge pedestals to form a sequence of vaulted shells. This model captures three cascading shell roofs (span 65 m, width 34 m, apex elevation 28 m) coupled to a stepped concourse deck supported on 28 concrete columns. WebCAE verifies shell membrane forces, rib load-sharing, natural vibration frequencies, and vault buckling safety under live crowd and dead load.

✓ Spherical Vault Shell Membrane Action✓ Precast Concrete Fan Rib Stiffening✓ Stepped Concourse Podium Frame✓ Shell Buckling & Vibration Modes
Contenedor .wce listo con campos de resultados
65×34 m · 1,027 beams · 976 quads · |u| = 37.7 mm · f₁ = 3.83 Hz · λ₁ = 55.8
Abrir modelo en App Web (WASM) →
Se abre directamente en la pestaña Resultados en 2 segundos sin recalcular¿Necesitas 1,5M+ GDL sin conexión? Obtener Pro ↓
Sydney Opera House Vaulted Roof Shells
65×34 m · 1,027 beams · 976 quads · |u| = 37.7 mm · f₁ = 3.83 Hz · λ₁ = 55.8Abrir 3D ↗
Footprint
65.0 × 34.0 m · Apex H = 28.0 m
Shell Vaults
3 pointed spherical shells
Columns & Ribs
1,027 beam members · 28 columns
Shell Quads
976 MITC4 elements (t = 120 mm)
Degrees of Freedom
5,988 DOF
Max Displacement
|u| = 37.7 mm (sail apex)
Fundamental Frequency
f₁ = 3.83 Hz
Buckling Margin
λ₁ = 55.8

1. Geometría y malla FEA

  • •Geometry: 3 cascading pointed spherical vault shells (Major Shell 1 span 26 m, H = 28 m; Shell 2 span 22 m, H = 22 m; Shell 3 span 17 m, H = 16 m) covering a 65 × 34 m footprint.
  • •Shell & rib framing: 976 MITC4 shell quad elements (t = 120 mm) stiffened by 1,027 fan precast concrete ribs (d1 = 0.60 m, d2 = 0.40 m) running along meridian circles.
  • •Podium substructure: multi-level stepped concourse deck slab supported by 28 reinforced concrete square columns (0.80 × 0.80 m, z = 0..4 m).
  • •Discretization: 1,053 structural joints, 1,027 beam elements, 976 shell quads, totaling 5,988 DOFs with verified topology closure.

2. Cargas y condiciones de contorno

  • •Fixed base column footings (all 6 DOFs) along the sea-level foundation line (z = 0).
  • •Uniform live crowd pressure (-3.0 kPa) on concourse deck panels and roof maintenance loading.
  • •Self-weight of reinforced concrete (E = 32 GPa, ν = 0.20, ρ = 2,500 kg/m³) applied across all shells and beams.

3. Resultados de simulación y conclusiones

  • ✓Maximum vertical static deflection |u| = 37.7 mm located at the cantilevered tip of the primary major sail shell.
  • ✓Fundamental natural frequency f₁ = 3.83 Hz corresponds to coupled lateral sail swaying and transverse podium racking.
  • ✓Eigenvalue buckling load factor λ₁ = 55.8 verifies high resistance to local snap-through or rib buckling under heavy combined gravity load.
Flujo de ingeniería y valor empresarial

WebCAE enables structural engineers to model and verify large-span vaulted shells and rib-stiffened curved architectures, confirming membrane action, rib-to-shell interaction, and dynamic stability within minutes in standard web browsers.

Abrir este caso en App Web →
Prueba gratuita de 14 días · $0 hoy
$99/ mes (facturación mensual tras 14 días de prueba)

14 días de acceso completo a Pro. El primer cobro se realiza tras 14 días salvo cancelación previa.

  • ✓Prueba de 14 días ($0 hoy) (cancela cuando quieras)
  • ✓Hasta 1,5M+ GDL (solucionador disperso directo)
  • ✓Apps nativas para Windows, macOS y Linux (100% offline)
  • ✓Contacto no lineal y pandeo (Kσ, MITC4, RBE2/RBE3)

$0 a pagar hoy. El primer cobro se realiza en 14 días salvo cancelación. Cancela en cualquier momento con 1 clic en tu cuenta.

¿Necesitas desarrollo de solucionadores a medida o un VPS en la nube dedicado (128+ GB RAM, 32 núcleos)?
Creamos flujos FEA sectoriales llave en mano y modelos de materiales a medida para equipos de ingeniería.

Pregunta a un ingeniero sobre tu modelo

Describe tu pieza, caso de carga o formato CAD — responderemos en 2 horas laborables.

Asistente de IA de WebCAE abajo a la derecha ↘

¿Quieres una respuesta instantánea sobre teoría FEA o este modelo?

Haz clic en el chat de IA en la esquina inferior derecha para consultar sobre condiciones de contorno, criterios de tensión, convergencia de malla o scripts DSL.

Usamos cookies esenciales para el funcionamiento de este sitio, además de cookies analíticas si lo aceptas. Política de privacidad