Ground-Effect Racing Diffuser Downforce and Pressure Recovery
Motorsport Aerodynamics (CFD)PASS · 2.13%Aerodynamic downforce and underbody Venturi diffuser pressure recovery for a ground-effect racing chassis with rear wing, verified against ground-effect wind-tunnel benchmark data.
- Tolerancia:
- 5%
Abrir y resolver en el navegadorInicie sesión o regístrese para abrir este modelo verificado en WebCAE
Abrir y resolver en el navegadorPlanteamiento del problema
- Geometría
- Racing chassis undertray with front splitter, Venturi throat (ground clearance h = 24 mm), upswept rear diffuser (expansion angle 16°), and inverted rear wing in wind tunnel 800 × 340 × 260 mm.
- Material
- Air at 20 °C (rho = 1.204 kg/m³, mu = 1.825e-5 Pa·s).
- Condiciones de contorno
- Inlet velocity U = 40 m/s along +X (intensity 5%), outlet gauge pressure 0 Pa, ground plane symmetry / slip, car body and wing no-slip viscous walls.
- Magnitud medida
- Aerodynamic downforce coefficient -CL (target 4.300) and diffuser static pressure recovery Delta_p from throat minimum pressure to duct exit.
Terminal WebCAE
Pegue estos comandos en el panel Terminal dentro de WebCAE. Utilizan el mismo DSL de texto que la aplicación; ejecute un comando por línea:
units mm
import path="cfd_motorsport_diffuser.step" format=step
mesh tet size=28
cfd fluid air
cfd set mode=steady speed=40 turbulence=sst iterations=180 tol=1e-4 threads=8 intensity=5
cfd inlet surface number 1 speed=40 intensity=0.05
cfd outlet surface number 6 pressure=0
cfd symmetry surface number 2
cfd symmetry surface number 3
cfd symmetry surface number 4
cfd symmetry surface number 5
cfd wall surface number 7 monitor=on
cfd wall surface number 8 monitor=on
cfd wall surface number 9 monitor=on
cfd wall surface number 10 monitor=on
cfd wall surface number 11 monitor=on
cfd wall surface number 12 monitor=on
cfd wall surface number 13 monitor=on
cfd wall surface number 14 monitor=on
cfd wall surface number 15 monitor=on
cfd wall surface number 16 monitor=on
cfd wall surface number 17 monitor=on
cfd wall surface number 18 monitor=on
cfd wall surface number 19 monitor=on
cfd wall surface number 20 monitor=on
cfd wall surface number 21 monitor=on
cfd wall surface number 22 monitor=on
solve cfdComparación de resultados
| Valor de referencia | 4.300 (-CL) |
| Resultado WebCAE | 4.208 (-CL) |
| Desviación | 2.13% |
| Tolerancia | 5% |
| Estado | PASS · 2.13% |
| Familia de elementos | Volúmenes finitos CFD |
| Detalles de malla | 4176 nodes, 18570 тет (Netgen P1 tet mesh, Venturi undertray + диффузор) |
Actualizado: 2026-10-19 · WebCAE 0.2.0 · 54751b2e+dirty