Ground-Effect Racing Diffuser Downforce and Pressure Recovery
Motorsport Aerodynamics (CFD)PASS · 2.13%Aerodynamic downforce and underbody Venturi diffuser pressure recovery for a ground-effect racing chassis with rear wing, verified against ground-effect wind-tunnel benchmark data.
- Tolerance:
- 5%
Open & Solve in BrowserSign in or register to launch this verified model in WebCAE
Open & Solve in BrowserProblem statement
- Geometry
- Racing chassis undertray with front splitter, Venturi throat (ground clearance h = 24 mm), upswept rear diffuser (expansion angle 16°), and inverted rear wing in wind tunnel 800 × 340 × 260 mm.
- Material
- Air at 20 °C (rho = 1.204 kg/m³, mu = 1.825e-5 Pa·s).
- Boundary conditions
- Inlet velocity U = 40 m/s along +X (intensity 5%), outlet gauge pressure 0 Pa, ground plane symmetry / slip, car body and wing no-slip viscous walls.
- Measured quantity
- Aerodynamic downforce coefficient -CL (target 4.300) and diffuser static pressure recovery Delta_p from throat minimum pressure to duct exit.
WebCAE Terminal
Paste these commands into the Terminal panel inside WebCAE. They use the same text DSL as the application; run one command per line:
units mm
import path="cfd_motorsport_diffuser.step" format=step
mesh tet size=28
cfd fluid air
cfd set mode=steady speed=40 turbulence=sst iterations=180 tol=1e-4 threads=8 intensity=5
cfd inlet surface number 1 speed=40 intensity=0.05
cfd outlet surface number 6 pressure=0
cfd symmetry surface number 2
cfd symmetry surface number 3
cfd symmetry surface number 4
cfd symmetry surface number 5
cfd wall surface number 7 monitor=on
cfd wall surface number 8 monitor=on
cfd wall surface number 9 monitor=on
cfd wall surface number 10 monitor=on
cfd wall surface number 11 monitor=on
cfd wall surface number 12 monitor=on
cfd wall surface number 13 monitor=on
cfd wall surface number 14 monitor=on
cfd wall surface number 15 monitor=on
cfd wall surface number 16 monitor=on
cfd wall surface number 17 monitor=on
cfd wall surface number 18 monitor=on
cfd wall surface number 19 monitor=on
cfd wall surface number 20 monitor=on
cfd wall surface number 21 monitor=on
cfd wall surface number 22 monitor=on
solve cfdResults comparison
| Reference value | 4.300 (-CL) |
| Our result | 4.208 (-CL) |
| Deviation | 2.13% |
| Tolerance | 5% |
| Status | PASS · 2.13% |
| Element family | Finite-volume CFD |
| Mesh details | 4176 узлов, 18570 тет (Netgen P1 tet mesh, Venturi undertray + диффузор) |
Updated: 2026-10-19 · WebCAE solver