NAFEMS T4

Heat transferPASS · 0.31%

Two-dimensional steady-state heat conduction with convective boundary conditions — temperature check at an edge point, solved as an exact 3D extrusion equivalent.

Tolerancia:
5%
Abrir y resolver en el navegadorInicie sesión o regístrese para abrir este modelo verificado en WebCAE
Abrir y resolver en el navegador

Planteamiento del problema

Geometría
Rectangle 0.6 m x 1.0 m (solved as a thin 3D extrusion in z with both z-faces insulated, which reproduces the 2D field exactly).
Material
Thermal conductivity k = 52 W/(m*C).
Condiciones de contorno
Edge AB (y = 0) held at 100 C; edge AD (x = 0) insulated; edges BC (x = 0.6) and CD (y = 1.0) convect with h = 750 W/(m^2*C) to a 0 C ambient.
Magnitud medida
Temperature at point E (0.6, 0.2) on edge BC — reference value 18.3 C.

Terminal WebCAE

Pegue estos comandos en el panel Terminal dentro de WebCAE. Utilizan el mismo DSL de texto que la aplicación; ejecute un comando por línea:

units m
material kappa=52
primitive box dx=0.6 dy=1.0 dz=0.05
mesh hex size=0.05
thermal surface number 1 temperature=100
thermal surface number 2 convection=750 ambient=0
thermal surface number 3 convection=750 ambient=0
solve thermal
probe temperature at=0.6,1.0,0.025

Comparación de resultados

Valor de referencia18.3 °C (TNSB-1990COMSOL даёт 18.25 °C)
Resultado WebCAE18.251 °C (96×160), 18.244 °C (48×80)
Desviación0.31%
Tolerancia5%
EstadoPASS · 0.31%
Familia de elementosElemento sólido
Detalles de mallahex8-экструзия 2D-постановки (z-грани изолированы), сетки 24×40 → 48×80 → 96×160: T(E) = 18.214 → 18.244 → 18.251 °C; (Dirichlet + Robin/конвекция), единицы СИ

Actualizado: 2026-08-10 · anterior a la numeración de versiones (anterior a 0.1.1)