Case Study: Full 3D P2 TET10 vs. 1D+2D Benchmark & Buckling on 26- and 17-Part Steel Frames
Load-for-load comparison of 26-part steel gantry (137,174 nodes, 400,308 active DOFs) and 17-part spatial truss (234,291 active DOFs): +3.23% to +3.48% static deflection parity, 3D joint compliance modal shifts, and buckling λ₁ = 27.905 / 86.532.

Why Compare 1D+2D Reduced Frames Against Full 3D P2 TET10 Solids
Dimensional reduction turns heavy multi-body steel frames into lightweight Timoshenko beams and Mindlin–Reissner shells — cutting degrees of freedom by orders of magnitude. Yet engineers rightly ask two honest questions:
1. Do deflections agree when both models carry the exact same load? In a previous case study (26-part portal gantry 1D–2D reduction), the reduced model carried -10 kPa on the deck. Here we verify exact load-for-load parity against a full 3D `P2 TET10` assembly (137,174 nodes, 66,803 quadratic tetrahedra, `400,308` active DOFs).
2. Where do 1D centerlines intentionally diverge from 3D joints? Centerline beam joints are infinitely rigid at intersection nodes, whereas real 3D I-beam flanges, web-to-flange fillets, and tangent brace welds deform locally — changing lateral sway frequencies and buckling margins.
Alongside the 26-part portal gantry (CAL_steel_gantry_26part_3d), we also verify a 17-part spatial truss frame (`A4_spatial_truss_gusset_frame`) under combined vertical deck pressure and 12% lateral wind load, including full 6-mode modal and 4-mode linear buckling analysis in native webcae_solve.

Model 1: 26-Part Portal Gantry in Full 3D P2 TET10 (CAL_steel_gantry_26part_3d)
- Geometry & materials:
26solids (6I-beam columns,4longitudinal I-beam girders,3box crossbeams,6X/Y tie struts,4circular diagonal braces,112 mmtop steel deck4200 x 2100 mm, and2underside stiffening ribs), isotropic steelE = 210 GPa,ν = 0.30,ρ = 7850 kg/m³. - Quadratic mesh (`netgen_tetmesh`):
maxh = 70 mm,order = 2(P2 TET10),137,174nodes,66,803elements,411,522raw DOFs (400,308active DOFs), `NegJac = 0`,minSICN = 0.01433. - 9,540 tied DAG constraint equations:
3,180slave nodes bond all load-bearing member faces while excluding4point-tangent brace-to-strut crossings (14<->20,15<->21,16<->22,17<->23) where braces remain welded at their column/girder ends. - Canonical `surface number N` addressing: All
6column bases are clamped (surface number 13,87,161,235,309,383) and the top deck is loaded onsurface number 1252.
Static Deflection Parity vs 1D+2D & Lateral Braking Subcase
| Subcase | 3D P2 TET10 ` | u | max` | 1D+2D Reduced ` | u | max` | Delta | Peak σ_vm (3D) | Reaction Error (Rx / Rz) |
|---|---|---|---|---|---|---|---|---|---|
10 kPa deck only | 2.0445 mm | 1.9807 mm | `+3.23%` | 87.67 MPa (elem) | 0.00043% | ||||
Gravity + 10 kPa deck | 2.2661 mm | 2.1898 mm | `+3.48%` | 97.22 MPa (elem) / 200.66 MPa (nodal) | 0.0065% | ||||
| Parity: Gravity + Patch 1 only | 0.2223 mm | 0.2092 mm | `+6.24%` | 9.54 MPa (elem) | 0.032% | ||||
Braking (+25.2 kN X + Gravity + 10 kPa) | 11.7232 mm | — | — | `153.32 MPa` (elem) | 0.0022% / 0.0068% |


Honest Modal Divergence: Why 3D Lateral Sway Is Softer Than 1D+2D
| Mode | 3D P2 TET10 (Hz) | 1D+2D Reduced (Hz) | Delta | Physical Interpretation |
|---|---|---|---|---|
f1 | 6.386 Hz | 10.026 Hz | `-36.3%` | Lateral sway softened by 3D I-beam flange & tangent brace compliance |
f2 | 9.155 Hz | 12.281 Hz | `-25.4%` | Global longitudinal/torsional frame compliance |
f3 | 11.577 Hz | 15.592 Hz | `-25.7%` | Coupled frame yaw/sway mode |
f4 | 39.906 Hz | 41.850 Hz | `-4.6%` | Local top-deck plate bending — converges closely with 2D shell |
f5 / f6 | 43.807 / 48.736 Hz | 43.485 / 43.767 Hz | +0.7% / +11.4% | Higher-order plate & rib modes |
Linear buckling (webcae_solve sparse eigensolver) reports `λ_1 = 27.905` (λ_2..4 = 37.061, 37.296, 49.319) under vertical load and `λ_1 = 27.891` (λ_2..4 = 33.368, 37.199, 41.977) under combined braking.
Model 2: 17-Part Spatial Truss Frame Under Combined Wind & Deck Load (A4_spatial_truss_gusset_frame)
To verify a braced 3D frame with full conformal bonding=1 mesh compatibility, A4_spatial_truss_gusset_frame combines 4 square columns (100 x 100 x 1500 mm), 8 mid/top box beams, 4 diagonal braces, and a 12 mm steel top deck (1300 x 1100 mm) — `17` solids, 78,295 nodes, 39,293 P2 TET10 elements (`234,291` active DOFs), NegJac = 0, minSICN = 0.02270:
- Canonical BCs:
fixon column bases (surface number 9,59,109,159), vertical10 kPadeck pressure (surface number 662,F_z = -14,300 N), and130 kPawindward edge load (surface number 657,F_x = +1,716 N,12.0%of vertical). - Equilibrium & peak stress:
|u|max = 2.8262 mm, peak nodal von Mises `143.46 MPa` at column-to-top-frame junction(45, 50, 1495) mm(col_1 = 143.46 MPa,top_deck = 93.60 MPa,beam_y_top_2 = 56.16 MPa), with exact reaction balance:Rx = -1,716.00 N(0.00014%error) andRz = +14,300.00 N(0.000025%error). - Modal & buckling: Natural frequencies
f1..f6 = [34.785, 37.069, 59.794, 74.726, 77.574, 78.447] Hz; linear buckling load factors `λ_1..λ_4 = [86.532, 137.625, 162.120, 222.303]`.




Download the Pre-Solved 3D .wce Projects & Canonical DSL Scripts
- Download 26-part 3D Gantry `.wce`: `CAL_steel_gantry_26part_3d.wce` (8.8 MB) · DSL (6.0 KB)
- Download 17-part Spatial Truss `.wce`: `A4_spatial_truss_gusset_frame.wce` (5.1 MB) · DSL (3.3 KB)
Drop either .wce file into app.webcae.com to inspect the full 3D P2 TET10 mesh, von Mises stress hotspots, and displacement fields interactively in your browser. Questions on 1D–2D vs 3D modeling trade-offs? Join Discord or Telegram.