Case Study: Unilateral Contact Prying & Coped-Web Buckling in Bolted Structural Steel Joints
8-body haunched end-plate moment joint (111,558 DOFs, 0.286% moment balance error, M20 bolt prying) and 5-body coped beam shear-tab joint (63,732 DOFs, bolt-hole bearing, and linear web buckling λ₁ = 3.889 / Q_cr = 291.69 kN).

Why Fastener Modeling & Boundary Conditions Break Structural Joint FEA
Bolted steel moment and shear connections look deceptively simple in CAD, yet two modeling mistakes routinely invalidate FEA predictions:
1. Over-constraining horizontal bolt shanks: In legacy scripted workflows, applying cylindrical normal constraints (component=normal) to horizontal bolt shanks inadvertently fixes their vertical Z and longitudinal X degrees of freedom. Instead of transferring vertical shear through bearing onto the supporting girder, the grounded bolts absorb load artificially — distorting endplate moments and cutting girder end reactions (for example, yielding -21.5 kN instead of +75.0 kN on a coped shear-tab joint).
2. Replacing unilateral contact with tied constraints: Gluing an endplate to a column flange hides the compression toe beneath the haunch, masks the wide mid-depth separation zone, and erases top-edge prying action.
In this dual case study, we solve both connections — the 8-body Haunched End-Plate Moment Connection (`CAL_haunched_endplate`) and the 5-body Coped Beam Shear-Tab Connection + Linear Buckling Sub-Model (`CAL_coped_beam_shear_tab`) — using fitted bearing bolts (`R_hole = R_shank = 10 mm`), quadratic `P2 TET10` meshes, unilateral Mortar `frictionless` contact, and canonical `surface number N` addressing in WebCAE's native solver (webcae_solve).

Case 1: Haunched End-Plate Beam-to-Column Joint (CAL_haunched_endplate)
Model Architecture, Mesh & Canonical Boundary Conditions
- Geometry (8 solids, 172 faces): HEB 220 column (
H = 220 mm,B = 220 mm,L = 700 mm, two12 mmtransverse stiffeners atZ = +110and-210 mm), haunched I-beam (H = 220 mm,L = 450 mm, triangular lower haunch200 × 100 mm,20 mmendplate220 × 390 mm), and6fitted M20 bolts (Bodies 3..8). - Material & Mesh (`netgen_tetmesh`): Structural steel (
E = 210 GPa,ν = 0.30,ρ = 7850 kg/m³),37,186nodes,19,557quadraticTET10elements,111,558DOFs, `NegJac = 0` (minSICN = 0.0464,avgSICN = 0.5376). - Canonical BCs & Loading: Bottom and top column ends fixed (
fix surface number 3,fix surface number 8); tip shear loadFz = -120,000 Napplied at beam end (surface number 239, moment arm470 mmto column faceX = 110 mm); unilateralcontact frictionlessacross all mating steel faces with zero artificial shank grounding.

Equilibrium Verification, Bolt Tension Gradient & Endplate Prying
- Exact Reaction Equilibrium: Column support reactions sum to
Rz = +120,000.0 N(`0.000%` error vs-120,000 N) andMy = -56,238.5 N·magainst the analytical56,400 N·mbending moment (`0.286%` error), with zero tensile contact forces (minContactNodalForce = 0). - Stress Distribution: Haunch tip
σ_vm = 180.06 MPa, beam/endplate peak759.06 MPa, column564.20 MPa, and local bolt-head/shank contact peak2,559.98 MPa(max |u| = 1.9890 mm, tipu_z = -1.8835 mm). - Symmetric Bolt Tension Gradient:
| Bolt Pair | Height Z (mm) | Axial Tension (N) | Shear F_z (N) | Peak σ_vm (MPa) |
|---|---|---|---|---|
| Top Row (Bolts 1 / 2) | +134.8 | 61,556.4 / 62,544.2 | 1,683.0 / 15.7 | 1,783.04 / 1,817.11 |
| Mid Row (Bolts 3 / 4) | +54.8 | 35,972.7 / 35,389.2 | 933.1 / 4,419.1 | 1,550.10 / 974.33 |
| Bottom Row (Bolts 5 / 6) | -175.2 | 7,095.7 / 7,500.4 | 3,787.5 / 1,734.9 | 2,559.98 / 2,188.31 |
- Z-Profile Contact Separation & Prying (`X = 110 mm`): Across the endplate face, `294` nodes remain in active compression (
p_c max = 297.94 MPa) while `1,385` nodes lift off in open separation up tou_x = +0.4996 mm: 1. Compression Toe (`Z = -231..-100 mm`):238active nodes (p_c max = 262.06 MPa) reacting flange/haunch thrust. 2. Web Separation Zone (`Z = -100..+150 mm`):989open nodes separating+0.0188..+0.4897 mmoff the column flange. 3. Top Prying Tip (`Z = +150..+161 mm`):4active nodes (p_c max = 83.37 MPa) capturing classic top-edge endplate prying.

Case 2: Coped Beam Shear Tab & Linear Web Buckling (CAL_coped_beam_shear_tab)
Resolving the Legacy Shank-Grounding Bug
In the 5-body coped beam connection (IPE 300 primary girder + 12 mm shear tab, coped IPE 200 secondary beam with R = 14 mm cope fillet, 3 M20 bolts at Z = -45, 0, +45 mm), removing artificial component=normal grounding on the horizontal shanks and switching to fitted bearing bolts (21,244 nodes, 10,421 TET10, 63,732 DOFs, NegJac = 0) with canonical BCs (fix surface number 1, 14; nut-end component=y on 240, 322, 404; shear load Fz = -75,000 N on surface number 120):
- Restores exact girder end reaction equilibrium: `Rz = +74,999.96 N` vs
-75,000 N(`0.00005%` balance error). - Captures the
R = 14 mmcope corner concentration (`σ_vm = 2,089.09 MPa`) and realistic outer-bolt bearing load sharing across1,113total active contact nodes (minFc = 0): - Bottom outer bolt (`Z = -45 mm`):78active hole nodes, webσ_vm = 8,618.93 MPa,p_c = 4,204.59 MPa- Middle bolt (`Z = 0 mm`):64active hole nodes, webσ_vm = 1,326.26 MPa,p_c = 1,027.26 MPa- Top outer bolt (`Z = +45 mm`):74active hole nodes, webσ_vm = 8,925.50 MPa,p_c = 5,616.24 MPa


Coped-Web Linear Buckling Sub-Model (λ_1 = 3.8892)
Isolating the coped secondary beam (22,665 nodes, 11,043 TET10, 67,995 DOFs, NegJac = 0), pinning all three bolt-hole cylinders (fix surface number 19, 20, 21), and applying Fz = -75,000 N at the beam tip (surface number 3) yields a pre-stress static deflection of 2.7581 mm (captured in CAL_coped_beam_shear_tab_buckling.wce) and native linear buckling eigenvalues:
| Buckling Mode | Load Factor λ | Critical Shear Q_cr = λ · 75 kN |
|---|---|---|
| Mode 1 | `3.8892` | `291.69 kN` |
| Mode 2 | 6.8676 | 515.07 kN |
| Mode 3 | 19.3658 | 1,452.44 kN |
| Mode 4 | 20.8790 | 1,565.93 kN |


Download Solved .wce Projects & Canonical .dsl Scripts
- Download `CAL_haunched_endplate.wce` (1.42 MB) · `CAL_haunched_endplate.dsl`
- Download `CAL_coped_beam_shear_tab.wce` (0.80 MB) · `CAL_coped_beam_shear_tab.dsl`
- Download `CAL_coped_beam_shear_tab_buckling.wce` (1.55 MB) · `CAL_coped_beam_shear_tab_buckling.dsl`
Drop any .wce file into app.webcae.com to inspect the P2 TET10 mesh, canonical surface number N supports, and unilateral contact fields. Join the engineering discussion on Discord or Telegram.