8-body haunched end-plate moment joint (111,558 DOFs, 0.286% moment balance error, M20 bolt prying) and 5-body coped beam shear-tab joint (63,732 DOFs, bolt-hole bearing, and linear web buckling λ₁ = 3.889 / Q_cr = 291.69 kN).

Von Mises stress across the 8-body haunched end-plate beam-to-column bolted connection in WebCAE

Why Fastener Modeling & Boundary Conditions Break Structural Joint FEA

Bolted steel moment and shear connections look deceptively simple in CAD, yet two modeling mistakes routinely invalidate FEA predictions:

1. Over-constraining horizontal bolt shanks: In legacy scripted workflows, applying cylindrical normal constraints (component=normal) to horizontal bolt shanks inadvertently fixes their vertical Z and longitudinal X degrees of freedom. Instead of transferring vertical shear through bearing onto the supporting girder, the grounded bolts absorb load artificially — distorting endplate moments and cutting girder end reactions (for example, yielding -21.5 kN instead of +75.0 kN on a coped shear-tab joint). 2. Replacing unilateral contact with tied constraints: Gluing an endplate to a column flange hides the compression toe beneath the haunch, masks the wide mid-depth separation zone, and erases top-edge prying action.

In this dual case study, we solve both connections — the 8-body Haunched End-Plate Moment Connection (`CAL_haunched_endplate`) and the 5-body Coped Beam Shear-Tab Connection + Linear Buckling Sub-Model (`CAL_coped_beam_shear_tab`) — using fitted bearing bolts (`R_hole = R_shank = 10 mm`), quadratic `P2 TET10` meshes, unilateral Mortar `frictionless` contact, and canonical `surface number N` addressing in WebCAE's native solver (webcae_solve).

8-body haunched end-plate beam-to-column bolted connection in WebCAE

Case 1: Haunched End-Plate Beam-to-Column Joint (CAL_haunched_endplate)

Model Architecture, Mesh & Canonical Boundary Conditions

  • Geometry (8 solids, 172 faces): HEB 220 column (H = 220 mm, B = 220 mm, L = 700 mm, two 12 mm transverse stiffeners at Z = +110 and -210 mm), haunched I-beam (H = 220 mm, L = 450 mm, triangular lower haunch 200 × 100 mm, 20 mm endplate 220 × 390 mm), and 6 fitted M20 bolts (Bodies 3..8).
  • Material & Mesh (`netgen_tetmesh`): Structural steel (E = 210 GPa, ν = 0.30, ρ = 7850 kg/m³), 37,186 nodes, 19,557 quadratic TET10 elements, 111,558 DOFs, `NegJac = 0` (minSICN = 0.0464, avgSICN = 0.5376).
  • Canonical BCs & Loading: Bottom and top column ends fixed (fix surface number 3, fix surface number 8); tip shear load Fz = -120,000 N applied at beam end (surface number 239, moment arm 470 mm to column face X = 110 mm); unilateral contact frictionless across all mating steel faces with zero artificial shank grounding.
Von Mises stress across haunched beam, endplate, and column web stiffeners in WebCAE

Equilibrium Verification, Bolt Tension Gradient & Endplate Prying

  • Exact Reaction Equilibrium: Column support reactions sum to Rz = +120,000.0 N (`0.000%` error vs -120,000 N) and My = -56,238.5 N·m against the analytical 56,400 N·m bending moment (`0.286%` error), with zero tensile contact forces (minContactNodalForce = 0).
  • Stress Distribution: Haunch tip σ_vm = 180.06 MPa, beam/endplate peak 759.06 MPa, column 564.20 MPa, and local bolt-head/shank contact peak 2,559.98 MPa (max |u| = 1.9890 mm, tip u_z = -1.8835 mm).
  • Symmetric Bolt Tension Gradient:
Bolt PairHeight Z (mm)Axial Tension (N)Shear F_z (N)Peak σ_vm (MPa)
Top Row (Bolts 1 / 2)+134.861,556.4 / 62,544.21,683.0 / 15.71,783.04 / 1,817.11
Mid Row (Bolts 3 / 4)+54.835,972.7 / 35,389.2933.1 / 4,419.11,550.10 / 974.33
Bottom Row (Bolts 5 / 6)-175.27,095.7 / 7,500.43,787.5 / 1,734.92,559.98 / 2,188.31
  • Z-Profile Contact Separation & Prying (`X = 110 mm`): Across the endplate face, `294` nodes remain in active compression (p_c max = 297.94 MPa) while `1,385` nodes lift off in open separation up to u_x = +0.4996 mm: 1. Compression Toe (`Z = -231..-100 mm`): 238 active nodes (p_c max = 262.06 MPa) reacting flange/haunch thrust. 2. Web Separation Zone (`Z = -100..+150 mm`): 989 open nodes separating +0.0188..+0.4897 mm off the column flange. 3. Top Prying Tip (`Z = +150..+161 mm`): 4 active nodes (p_c max = 83.37 MPa) capturing classic top-edge endplate prying.
Unilateral Mortar contact pressure on isolated endplate face showing compression toe and open separation

Case 2: Coped Beam Shear Tab & Linear Web Buckling (CAL_coped_beam_shear_tab)

Resolving the Legacy Shank-Grounding Bug

In the 5-body coped beam connection (IPE 300 primary girder + 12 mm shear tab, coped IPE 200 secondary beam with R = 14 mm cope fillet, 3 M20 bolts at Z = -45, 0, +45 mm), removing artificial component=normal grounding on the horizontal shanks and switching to fitted bearing bolts (21,244 nodes, 10,421 TET10, 63,732 DOFs, NegJac = 0) with canonical BCs (fix surface number 1, 14; nut-end component=y on 240, 322, 404; shear load Fz = -75,000 N on surface number 120):

  • Restores exact girder end reaction equilibrium: `Rz = +74,999.96 N` vs -75,000 N (`0.00005%` balance error).
  • Captures the R = 14 mm cope corner concentration (`σ_vm = 2,089.09 MPa`) and realistic outer-bolt bearing load sharing across 1,113 total active contact nodes (minFc = 0): - Bottom outer bolt (`Z = -45 mm`): 78 active hole nodes, web σ_vm = 8,618.93 MPa, p_c = 4,204.59 MPa - Middle bolt (`Z = 0 mm`): 64 active hole nodes, web σ_vm = 1,326.26 MPa, p_c = 1,027.26 MPa - Top outer bolt (`Z = +45 mm`): 74 active hole nodes, web σ_vm = 8,925.50 MPa, p_c = 5,616.24 MPa
Coped beam R14 notch concentration and bolt-hole bearing von Mises stress in WebCAE
Bolt-hole bearing contact pressure on the isolated coped secondary beam web

Coped-Web Linear Buckling Sub-Model (λ_1 = 3.8892)

Isolating the coped secondary beam (22,665 nodes, 11,043 TET10, 67,995 DOFs, NegJac = 0), pinning all three bolt-hole cylinders (fix surface number 19, 20, 21), and applying Fz = -75,000 N at the beam tip (surface number 3) yields a pre-stress static deflection of 2.7581 mm (captured in CAL_coped_beam_shear_tab_buckling.wce) and native linear buckling eigenvalues:

Buckling ModeLoad Factor λCritical Shear Q_cr = λ · 75 kN
Mode 1`3.8892``291.69 kN`
Mode 26.8676515.07 kN
Mode 319.36581,452.44 kN
Mode 420.87901,565.93 kN
Pre-stress static sub-model for coped-web buckling in WebCAE
Bolted structural steel joints verification chart: bolt tensions, endplate contact Z-profile, bearing and buckling

Download Solved .wce Projects & Canonical .dsl Scripts

Drop any .wce file into app.webcae.com to inspect the P2 TET10 mesh, canonical surface number N supports, and unilateral contact fields. Join the engineering discussion on Discord or Telegram.