WebCAE
Platform Overview (PDF)
← Back to blog
GuidesNovember 23, 2026

Bracket Stress Analysis from a STEP File: A Worked FEA Example

Worked linear static Tet10 analysis of a structural steel L-bracket (l_bracket_hex_decomp.step) in WebCAE: canonical surface number N setup, 3-mesh convergence against Euler-Bernoulli bending (94.30 → 93.17 MPa vs. 91.56 → 90.48 MPa), and why peak stress at a rigid support diverges (133.99 → 501.75 MPa).

3D mesh and structural geometry of the steel L-bracket (l_bracket_hex_decomp.step) in WebCAE

1. Geometry, Downloadable STEP Model & Material Inputs

To study a real CAD-to-FEA bracket workflow end to end without hiding behind hand-picked numbers, we start from a clean single-solid B-Rep L-bracket exported as a standard STEP file:

  • Downloadable CAD input: Download l_bracket_hex_decomp.step (27.9 KB) (27,902 bytes)
  • Overall bounding box: 80 × 40 × 70 mm (x ∈ [0, 80] mm, y ∈ [0, 40] mm, z ∈ [0, 70] mm)
  • Sub-regions fused into one solid: 80 × 40 × 10 mm horizontal cantilever arm (z ∈ [0, 10] mm) + 10 × 40 × 60 mm upright mounting leg (x ∈ [0, 10] mm, z ∈ [10, 70] mm)
  • Exact B-Rep topology & mass properties: volume 56,000 mm³, surface area 14,800 mm², 11 B-Rep faces, and an unfilleted sharp 90° re-entrant inner corner along x = 10 mm, z = 10 mm
  • Material (Structural Steel): Young's modulus E = 200 GPa (200,000 MPa in the WebCAE UI material field / 200e9 Pa in DSL), Poisson's ratio ν = 0.3, density ρ = 7,850 kg/m³

Because the STEP file carries exact analytical B-Rep faces rather than faceted triangles, WebCAE's OpenCASCADE kernel (OCCT) imports the part in millimetres and assigns every face a deterministic model-tree index (surface number N) for boundary conditions and loads.


2. Boundary Conditions, Load & Quadratic Tet10 Mesh Setup

In this worked cantilever setup (Setup D), the upright leg mounts flush against a rigid vertical wall while the horizontal arm tip carries a downward vertical shear load of 1,000 N:

  • Fixed support (`Fixed support` in UI → `Loads/BC`): applied to the upright back mounting face at x = 0, z ∈ [10, 70] mm (40 × 60 mm, area 2,400 mm²), constraining all three translations (u_x = u_y = u_z = 0). In the model tree and DSL, this face is surface number 3.
  • Applied tip load (`Force` in UI → `Loads/BC`): vertical downward force Fz = -1,000 N distributed across the horizontal arm tip face at x = 80 mm, z ∈ [0, 10] mm (40 × 10 mm, area 400 mm²), addressed as surface number 6.
  • Mesh 1 — `4 mm` baseline (`netgen_tetmesh`): uniform quadratic Tet10 (order=2, maxh = 4 mm).
  • Mesh 2 — `2 mm` uniform refinement: global maxh = 2 mm (Tet10, order=2) to test convergence across the arm and inner corner.
  • Mesh 3 — `0.5 mm` local fixed-edge refinement: 4 mm background mesh plus three spherical local sizing zones (size = 0.5 mm) centered along the clamped edge transition at x = 0, z = 10 mm (at=0,20,10 r=6, at=0,0,10 r=4, at=0,40,10 r=4).

Every step from STEP import to native static solution (webcae_solve) maps directly between the WebCAE ribbon UI and canonical DSL:

units mm
import "l_bracket_hex_decomp.step"
material E=200e9 nu=0.3 density=7850

# Baseline 4 mm quadratic Tet10 mesh (switch to size=2 or add refine zones below)
mesh tet size=4 order=2

# Optional local 0.5 mm refinement along the fixed support edge (x = 0, z = 10 mm)
# refine zone at=0,20,10 r=6 size=0.5
# refine zone at=0,0,10 r=4 size=0.5
# refine zone at=0,40,10 r=4 size=0.5

# Canonical model-tree surface addressing
fix surface number 3
load surface number 6 force=0,0,-1000

solve static

Note the unit convention when switching between GUI and script: the WebCAE UI Material panel accepts Young's modulus in MPa (200000), whereas the DSL material E= argument always expects Pascals (200e9).


3. Native Solver Results Across All Three Meshes

All three quadratic Tet10 meshes were generated with netgen_tetmesh and solved with WebCAE's native linear static solver (webcae_solve).

Mesh size, degrees of freedom, timing & tip deflection

Mesh configurationElements (Tet10)NodesFree DOFMesh / Solve / Wall (ms)Max displacement (mm)
`4 mm` uniform3,9657,58120,418249 / 265 / 2780.2501
`2 mm` uniform30,33249,495139,6261,263 / 3,499 / 3,5520.2562
`4 mm + 0.5 mm` local (`x = 0, z = 10`)35,79852,514150,2251,393 / 10,735 / 10,7960.2568

Regional von Mises stress vs. analytical bending reference

To separate real structural behavior from geometric singularities, we probe von Mises stress (σ_vm) in three distinct zones — reporting both P2 nodal recovery and raw element-centroid values:

Mesh configurationArm bending (~x = 19 mm) P2 / Centroid (MPa)Analytical σ = 6·F·L_eff / (b·t²) (MPa)Diff (P2 vs. analytical)Re-entrant corner (x=10, z=10) P2 / Centroid (MPa)Fixed edge (x=0, z=10) P2 / Centroid (MPa)
`4 mm` uniform94.30 / 78.46 (x = 18.96 mm)91.562.993%111.12 / 48.20133.99 / 60.56
`2 mm` uniform94.29 / 86.08 (x = 18.98 mm)91.533.015%167.31 / 113.98210.20 / 102.06
`4 mm + 0.5 mm` local93.17 / 76.97 (x = 19.68 mm)90.482.973%146.08 / 83.53501.75 / 259.79
  • Nominal arm probe positions (`z = 0` bottom tension skin): [18.96, 1.70, 0] mm (4 mm), [18.98, 1.74, 0] mm (2 mm), and [19.68, 38.30, 0] mm (4 mm + 0.5 mm local), giving effective moment arms L_eff = 80 - x = 61.04, 61.02, and 60.32 mm for b = 40 mm, t = 10 mm, and F = 1,000 N.
  • Global element-centroid peak (`solverCentroidGlobalMaxVmMpa`): rises from 100.36 MPa (at [0, 0, 8.33] mm) on 4 mm, to 159.81 MPa (at [0, 40, 9] mm) on 2 mm, to 299.45 MPa (at [0, 1.26, 9.78] mm) on 0.5 mm local — chasing the same clamped boundary line.

4. Analytical Verification & Why Peak Stress at a Fixed Support Misleads

Comparing the three meshes side by side exposes the single most common trap in linear static FEA of CAD brackets:

  • 1. Global stiffness and nominal arm bending converge cleanly: Maximum tip displacement settles smoothly from 0.2501 mm (4 mm) to 0.2562 mm (2 mm) and 0.2568 mm (0.5 mm local) — only a 0.23% shift between the last two meshes. Meanwhile, away from corners at x ≈ 19 mm, the 3D Tet10 P2 nodal von Mises stress locks straight onto Euler-Bernoulli cantilever theory (σ = 6·F·L_eff / (b·t²)): 94.30 MPa vs. 91.56 MPa (2.993%), 94.29 MPa vs. 91.53 MPa (3.015%), and 93.17 MPa vs. 90.48 MPa (2.973%). That steady ~3.0% margin reflects physical 3D Poisson anticlastic curvature (ν = 0.3) and transverse shear near the plate edge, not numerical error.
  • 2. Sharp geometric corners concentrate stress: Even at the unfilleted 90° re-entrant inner corner (x = 10 mm, z = 10 mm), refining uniformly from 4 mm to 2 mm pushes P2 nodal stress from 111.12 MPa to 167.31 MPa (and centroid stress from 48.20 to 113.98 MPa), while keeping 4 mm background grading on the third mesh drops that probe back to 146.08 MPa simply because the 0.5 mm zones stayed near x = 0.
  • 3. Peak stress on a zero-compliance rigid support diverges unboundedly: Right on the bottom edge of fix surface number 3 (x = 0, z = 10 mm), where every node transitions abruptly from u_x = u_y = u_z = 0 to a traction-free face across a 90° corner, P2 nodal von Mises stress climbs from `133.99 MPa` (4 mm) to `210.20 MPa` (2 mm) and spikes to `501.75 MPa` under 0.5 mm local refinement (with centroid stress jumping 60.56 → 102.06 → 259.79 MPa). There is no converged value here: mathematically, clamping displacements to zero on a sharp geometric boundary produces a theoretical 1/r^λ stress singularity that approaches infinity as element size h → 0.

Practical engineering rules when reading bracket FEA results

  • Never take global `max σ_vm` on a sharp fixed boundary as a material failure limit: If refining a mesh near a rigid Fixed support doubles the peak stress while displacement barely moves (0.2562 → 0.2568 mm), you are resolving a boundary singularity, not physical yielding.
  • Verify nominal sections against hand calculations first: Checking σ = 6·F·L_eff / (b·t²) away from supports (94.30 MPa vs. 91.56 MPa) confirms units, load direction, constraint orientation, and element formulation in seconds.
  • Model real mounting compliance and fillets when joint peak stress governs design: Add true manufacturing fillets at re-entrant corners like x = 10, z = 10 mm, and replace idealized rigid face clamps with bolted washers, compliant pads, or multi-body contact when sizing the mounting interface itself.

5. Open the Model & Continue Exploring in WebCAE

You can inspect this bracket directly or explore the broader STEP-to-FEA workflow in WebCAE:

We use essential cookies to run this site, plus analytics cookies if you agree. Privacy Policy