Bracket Stress Analysis from a STEP File: A Worked FEA Example
Worked linear static Tet10 analysis of a structural steel L-bracket (l_bracket_hex_decomp.step) in WebCAE: canonical surface number N setup, 3-mesh convergence against Euler-Bernoulli bending (94.30 → 93.17 MPa vs. 91.56 → 90.48 MPa), and why peak stress at a rigid support diverges (133.99 → 501.75 MPa).
1. Geometry, Downloadable STEP Model & Material Inputs
To study a real CAD-to-FEA bracket workflow end to end without hiding behind hand-picked numbers, we start from a clean single-solid B-Rep L-bracket exported as a standard STEP file:
- Downloadable CAD input: Download l_bracket_hex_decomp.step (27.9 KB) (27,902 bytes)
- Overall bounding box:
80 × 40 × 70 mm(x ∈ [0, 80] mm,y ∈ [0, 40] mm,z ∈ [0, 70] mm) - Sub-regions fused into one solid:
80 × 40 × 10 mmhorizontal cantilever arm (z ∈ [0, 10] mm) +10 × 40 × 60 mmupright mounting leg (x ∈ [0, 10] mm,z ∈ [10, 70] mm) - Exact B-Rep topology & mass properties: volume
56,000 mm³, surface area14,800 mm²,11B-Rep faces, and an unfilleted sharp 90° re-entrant inner corner alongx = 10 mm, z = 10 mm - Material (Structural Steel): Young's modulus
E = 200 GPa(200,000 MPain the WebCAE UI material field /200e9 Pain DSL), Poisson's ratioν = 0.3, densityρ = 7,850 kg/m³
Because the STEP file carries exact analytical B-Rep faces rather than faceted triangles, WebCAE's OpenCASCADE kernel (OCCT) imports the part in millimetres and assigns every face a deterministic model-tree index (surface number N) for boundary conditions and loads.
2. Boundary Conditions, Load & Quadratic Tet10 Mesh Setup
In this worked cantilever setup (Setup D), the upright leg mounts flush against a rigid vertical wall while the horizontal arm tip carries a downward vertical shear load of 1,000 N:
- Fixed support (`Fixed support` in UI → `Loads/BC`): applied to the upright back mounting face at
x = 0, z ∈ [10, 70] mm(40 × 60 mm, area2,400 mm²), constraining all three translations (u_x = u_y = u_z = 0). In the model tree and DSL, this face issurface number 3. - Applied tip load (`Force` in UI → `Loads/BC`): vertical downward force
Fz = -1,000 Ndistributed across the horizontal arm tip face atx = 80 mm, z ∈ [0, 10] mm(40 × 10 mm, area400 mm²), addressed assurface number 6. - Mesh 1 — `4 mm` baseline (`netgen_tetmesh`): uniform quadratic
Tet10(order=2,maxh = 4 mm). - Mesh 2 — `2 mm` uniform refinement: global
maxh = 2 mm(Tet10,order=2) to test convergence across the arm and inner corner. - Mesh 3 — `0.5 mm` local fixed-edge refinement:
4 mmbackground mesh plus three spherical local sizing zones (size = 0.5 mm) centered along the clamped edge transition atx = 0, z = 10 mm(at=0,20,10 r=6,at=0,0,10 r=4,at=0,40,10 r=4).
Every step from STEP import to native static solution (webcae_solve) maps directly between the WebCAE ribbon UI and canonical DSL:
units mm
import "l_bracket_hex_decomp.step"
material E=200e9 nu=0.3 density=7850
# Baseline 4 mm quadratic Tet10 mesh (switch to size=2 or add refine zones below)
mesh tet size=4 order=2
# Optional local 0.5 mm refinement along the fixed support edge (x = 0, z = 10 mm)
# refine zone at=0,20,10 r=6 size=0.5
# refine zone at=0,0,10 r=4 size=0.5
# refine zone at=0,40,10 r=4 size=0.5
# Canonical model-tree surface addressing
fix surface number 3
load surface number 6 force=0,0,-1000
solve staticNote the unit convention when switching between GUI and script: the WebCAE UI Material panel accepts Young's modulus in MPa (200000), whereas the DSL material E= argument always expects Pascals (200e9).
3. Native Solver Results Across All Three Meshes
All three quadratic Tet10 meshes were generated with netgen_tetmesh and solved with WebCAE's native linear static solver (webcae_solve).
Mesh size, degrees of freedom, timing & tip deflection
| Mesh configuration | Elements (Tet10) | Nodes | Free DOF | Mesh / Solve / Wall (ms) | Max displacement (mm) |
|---|---|---|---|---|---|
| `4 mm` uniform | 3,965 | 7,581 | 20,418 | 249 / 265 / 278 | 0.2501 |
| `2 mm` uniform | 30,332 | 49,495 | 139,626 | 1,263 / 3,499 / 3,552 | 0.2562 |
| `4 mm + 0.5 mm` local (`x = 0, z = 10`) | 35,798 | 52,514 | 150,225 | 1,393 / 10,735 / 10,796 | 0.2568 |
Regional von Mises stress vs. analytical bending reference
To separate real structural behavior from geometric singularities, we probe von Mises stress (σ_vm) in three distinct zones — reporting both P2 nodal recovery and raw element-centroid values:
| Mesh configuration | Arm bending (~x = 19 mm) P2 / Centroid (MPa) | Analytical σ = 6·F·L_eff / (b·t²) (MPa) | Diff (P2 vs. analytical) | Re-entrant corner (x=10, z=10) P2 / Centroid (MPa) | Fixed edge (x=0, z=10) P2 / Centroid (MPa) |
|---|---|---|---|---|---|
| `4 mm` uniform | 94.30 / 78.46 (x = 18.96 mm) | 91.56 | 2.993% | 111.12 / 48.20 | 133.99 / 60.56 |
| `2 mm` uniform | 94.29 / 86.08 (x = 18.98 mm) | 91.53 | 3.015% | 167.31 / 113.98 | 210.20 / 102.06 |
| `4 mm + 0.5 mm` local | 93.17 / 76.97 (x = 19.68 mm) | 90.48 | 2.973% | 146.08 / 83.53 | 501.75 / 259.79 |
- Nominal arm probe positions (`z = 0` bottom tension skin):
[18.96, 1.70, 0] mm(4 mm),[18.98, 1.74, 0] mm(2 mm), and[19.68, 38.30, 0] mm(4 mm + 0.5 mmlocal), giving effective moment armsL_eff = 80 - x = 61.04,61.02, and60.32 mmforb = 40 mm,t = 10 mm, andF = 1,000 N. - Global element-centroid peak (`solverCentroidGlobalMaxVmMpa`): rises from
100.36 MPa(at[0, 0, 8.33] mm) on4 mm, to159.81 MPa(at[0, 40, 9] mm) on2 mm, to299.45 MPa(at[0, 1.26, 9.78] mm) on0.5 mmlocal — chasing the same clamped boundary line.
4. Analytical Verification & Why Peak Stress at a Fixed Support Misleads
Comparing the three meshes side by side exposes the single most common trap in linear static FEA of CAD brackets:
- 1. Global stiffness and nominal arm bending converge cleanly: Maximum tip displacement settles smoothly from
0.2501 mm(4 mm) to0.2562 mm(2 mm) and0.2568 mm(0.5 mmlocal) — only a0.23%shift between the last two meshes. Meanwhile, away from corners atx ≈ 19 mm, the 3DTet10P2 nodal von Mises stress locks straight onto Euler-Bernoulli cantilever theory (σ = 6·F·L_eff / (b·t²)):94.30 MPavs.91.56 MPa(2.993%),94.29 MPavs.91.53 MPa(3.015%), and93.17 MPavs.90.48 MPa(2.973%). That steady ~3.0%margin reflects physical 3D Poisson anticlastic curvature (ν = 0.3) and transverse shear near the plate edge, not numerical error. - 2. Sharp geometric corners concentrate stress: Even at the unfilleted
90°re-entrant inner corner (x = 10 mm, z = 10 mm), refining uniformly from4 mmto2 mmpushes P2 nodal stress from111.12 MPato167.31 MPa(and centroid stress from48.20to113.98 MPa), while keeping4 mmbackground grading on the third mesh drops that probe back to146.08 MPasimply because the0.5 mmzones stayed nearx = 0. - 3. Peak stress on a zero-compliance rigid support diverges unboundedly: Right on the bottom edge of
fix surface number 3(x = 0, z = 10 mm), where every node transitions abruptly fromu_x = u_y = u_z = 0to a traction-free face across a90°corner, P2 nodal von Mises stress climbs from `133.99 MPa` (4 mm) to `210.20 MPa` (2 mm) and spikes to `501.75 MPa` under0.5 mmlocal refinement (with centroid stress jumping60.56 → 102.06 → 259.79 MPa). There is no converged value here: mathematically, clamping displacements to zero on a sharp geometric boundary produces a theoretical1/r^λstress singularity that approaches infinity as element sizeh → 0.
Practical engineering rules when reading bracket FEA results
- Never take global `max σ_vm` on a sharp fixed boundary as a material failure limit: If refining a mesh near a rigid
Fixed supportdoubles the peak stress while displacement barely moves (0.2562 → 0.2568 mm), you are resolving a boundary singularity, not physical yielding. - Verify nominal sections against hand calculations first: Checking
σ = 6·F·L_eff / (b·t²)away from supports (94.30 MPavs.91.56 MPa) confirms units, load direction, constraint orientation, and element formulation in seconds. - Model real mounting compliance and fillets when joint peak stress governs design: Add true manufacturing fillets at re-entrant corners like
x = 10, z = 10 mm, and replace idealized rigid face clamps with bolted washers, compliant pads, or multi-body contact when sizing the mounting interface itself.
5. Open the Model & Continue Exploring in WebCAE
You can inspect this bracket directly or explore the broader STEP-to-FEA workflow in WebCAE:
- Download the exact STEP geometry: Download l_bracket_hex_decomp.step (27.9 KB) and drag it into Open STEP workflow in WebCAE to apply
fix surface number 3,load surface number 6 force=0,0,-1000, and run theTet10mesh ladder locally in your browser. - Start from the pre-meshed 3-cell hex bracket: Open L-bracket hex mesh opens
l_bracket_hex_decomp.wce(680 HEX8elements,1,155nodes across3sweep cells, ready for your boundary conditions). - Inspect a solved aerospace bracket case: Open solved dual-lug bracket or read the wing lug fitting showcase.
- Read related guides: STEP to FEA workflow, Online FEA solver capabilities, and FEA mesh convergence guide.