WebCAE
WebCAE PlatformUnified FEA & CFD simulation platform: Browser WebAssembly + Native Desktop

Inspect pre-solved models in your browser in 2 seconds (up to 300k DOF) or solve 1.5M+ DOF assemblies 100% offline on Windows, macOS, and Linux.

Browser WASM
Up to 300k DOF · 2s load
Native Desktop (Pro)
Up to 1.5M+ DOF · 100% offline
Physics & Solvers
Static, Modal, Kσ, Contact, CFD
ISO 7206-4 Biomedical Assembly · Ti-6Al-4V + CoCrMo · RBE2 Spider · TET10MachineryMulti-Body Contact Assembly

Total Hip Arthroplasty Implant (ISO 7206-4): Ti-6Al-4V Stem & CoCrMo Head

Two-body orthopedic fatigue-test assembly (Ti-6Al-4V ELI femoral stem + CoCrMo Ø32 mm modular head joined across a 12/14 Morse taper via Bonded MPC) under a 2,300 N vertical hip joint reaction force applied through an RBE2 spider at the head center.

ISO 7206-4 specifies the endurance test setup for total hip joint prostheses: the distal femoral stem is potted in bone cement while a vertical test load F_z = −2,300 N is applied through the center of the modular femoral head at a 30 mm medial offset (bending moment M = 69 N·m). This 2-body CAD assembly models the Ti-6Al-4V ELI stem (E = 114 GPa, ν = 0.34) and CoCrMo Ø32 mm head (E = 220 GPa, ν = 0.30) coupled across their conical Morse taper via Bonded MPC, with an RBE2 spider transferring F_z = −2,300 N from the head center (30, 0, 130) mm onto the upper bearing hemisphere.

✓ Bi-Metallic Assembly (Ti-6Al-4V + CoCrMo)✓ 12/14 Morse Taper Bonded MPC Interface✓ RBE2 Spherical Head Spider Load (ISO 7206-4)✓ Combined Bending & Compression Neck Verification
Pre-solved .wce container ready
2 bodies · 1,861 TET10 (3,077 nodes) · Fz = −2,300 N · σ_vm = 180.7 MPa · |U| = 0.194 mm
Open in Web App (WASM) →
Opens directly on the Results tab in 2 seconds without re-solvingNeed 1.5M+ DOF offline? Get Pro ↓
Total Hip Arthroplasty Implant (ISO 7206-4): Ti-6Al-4V Stem & CoCrMo Head
2 bodies · 1,861 TET10 (3,077 nodes) · Fz = −2,300 N · σ_vm = 180.7 MPa · |U| = 0.194 mmLaunch 3D ↗
Material Pair
Ti-6Al-4V ELI (114 GPa) / CoCrMo (220 GPa)
ISO 7206-4 Test Load
F_z = −2,300 N at (30, 0, 130) mm (M = 69 N·m)
Finite Elements
1,861 TET10 (9,231 DOF, 3,077 nodes, 2 bodies)
Peak Neck Stress σ_vM
180.7 MPa (analytical 180.5 MPa, err 0.14%)
Head Deflection |U|
0.1942 mm
Yield Safety Factor
n_y = 4.40 (σ_Y = 795 MPa)

1. Geometry & FEA Mesh

  • •2 B-Rep solid bodies: Body 1 — Ti-6Al-4V ELI femoral stem with distal cement fixation zone, curved transition, Ø14 mm neck, and Morse taper trunnion; Body 2 — CoCrMo Ø32 mm modular femoral head.
  • •Region-specific materials: Ti-6Al-4V ELI (E = 114,000 MPa, ν = 0.34, ρ = 4,430 kg/m³) on Body 1 and ASTM F1537 CoCrMo (E = 220,000 MPa, ν = 0.30, ρ = 8,300 kg/m³) on Body 2.
  • •2nd-order curved tetrahedral mesh (P2 / TET10): 1,861 elements, 3,077 nodes, and 9,231 DOFs (single-step linear static solve without multi-step slider).

2. Loads & Boundary Conditions

  • •Fixed support (Ux = Uy = Uz = 0) on the distal potted stem surfaces (surfaces 1, 2, 3 up to z = 50 mm).
  • •Bonded (MPC) contact pair across the conical Morse taper interface between Body 1 and Body 2.
  • •Remote Force (RBE2 spider) F_z = −2,300 N at reference point (30, 0, 130) mm coupled to the upper bearing hemisphere of the CoCrMo head (surface 8).

3. Simulation Results & Findings

  • ✓Peak von Mises stress σ_vm = 180.72 MPa at the lateral neck–stem transition (within 0.14% of combined Euler–Bernoulli bending + axial compression theory σ_nom = 180.47 MPa and 4.3× below the 795 MPa yield strength of Ti-6Al-4V ELI).
  • ✓Maximum head displacement |U|_max = 0.1942 mm at the CoCrMo femoral head.
  • ✓Exact vertical reaction equilibrium R_z = +2,300.0 N (0.00% error) and overturning moment M_y = 69.00 N·m.
Enterprise & Engineering Workflow

WebCAE enables medical device engineers to run ISO 7206-4 bi-metallic hip implant stress and stiffness checks with true CAD geometry, Morse taper MPC coupling, and RBE2 spherical head loading in seconds.

Launch Case in Web App →
14-Day Free Trial · $0 Due Today
$99/ mo (billed monthly after 14-day trial)

14 days of full Pro access. The first charge occurs only after 14 days unless canceled beforehand.

  • ✓14-Day Trial ($0 Today) (cancel anytime)
  • ✓Up to 1.5M+ DOFs (direct sparse solver)
  • ✓Native Windows, macOS & Linux Apps (100% offline)
  • ✓Nonlinear Contact & Buckling (Kσ, MITC4, RBE2/RBE3)

$0 due today. First charge occurs in 14 days unless cancelled. Cancel anytime in 1 click in your account.

Need bespoke solver development or a Dedicated Cloud VPS (128+ GB RAM, 32 cores)?
We build turnkey industry FEA pipelines and custom material models for engineering teams.

Ask an Engineer About Your Model

Describe your part, load case, or CAD format — we reply within 2 business hours.

WebCAE AI Assistant in bottom-right ↘

Want an instant answer on FEA theory or this model?

Click the AI chat button in the bottom-right corner to ask about boundary conditions, stress criteria, mesh convergence, or DSL scripting.

We use essential cookies to run this site, plus analytics cookies if you agree. Privacy Policy