WebCAE
← All cases

Contact — Uniform Patch

ContactPASS · 0.01%

Unilateral, frictional, sliding, or interference-contact verification. Checks: constant pressure transmission and force conservation.

Tolerance:
5%
Open & Solve in BrowserSign in or register to launch this verified model in WebCAE
Open & Solve in Browser

Problem statement

Geometry
Two prismatic blocks in uniform compression: A=100 mm2, h1=20 mm, E1=1000 MPa, h2=30 mm, E2=2000 MPa, nu1=nu2=0, P=100 N.
Material
Constitutive or analytical definition: p=P/A; delta=P(h1/(E1 A)+h2/(E2 A)).
Boundary conditions
Required solver capability: frictionless_contact. Use the loading/path control stated in the setup and preserve the complete response history.
Measured quantity
Uniform pressure=1 MPa, total shortening=0.035 mm, integrated contact reaction=100 N, tangential traction=0.

WebCAE Terminal

Paste these commands into the Terminal panel inside WebCAE. They use the same text DSL as the application; run one command per line:

units mm
material E=1000 nu=0.0
import path="uniform_patch_block1.step" format=step
material E=2000 nu=0.0
import path="uniform_patch_block2.step" format=step
contact frictionless
mesh tet size=2.5 order=1 bonding=0
fix surface number 1
fix surface number 3 component=x
fix surface number 3 component=y
load surface number 2 pressure=1.0
solve
minmax displacement_magnitude

Results comparison

Reference value0.035 mm
Our result0.03500 mm
Deviation0.01%
Tolerance5%
StatusPASS · 0.01%
Element familySolid element
Mesh details2 призматических блока 10×10 мм, 108 узлов, 240 тет